APAR status
Closed as program error.
Error description
Customer tries to run Netezza sequentially to reduce connections, however it ignores the -seq and gives a warning in the log.
Local fix
This fix is included in 8.0.1 fix pack 3
Problem summary
**************************************************************** USERS AFFECTED: Netezza Read and Write Operator **************************************************************** PROBLEM DESCRIPTION: PROBLEM: Unable to execute Netezza operator in sequential mode with multi-node config file. DETAILS: When the Netezza Enterprise stage property is set to "sequential" in the stage while running the job, user gets the following warning and the stage runs in parallel mode. "When checking operator: Ignorning the requested execution mode [seq] because of a conflict with the pre-defined mode of the operator." **************************************************************** RECOMMENDATION: Apply the APAR. ****************************************************************
Problem conclusion
Modified the code to execute the stage which is set "sequential" to execute on a single node.
Temporary fix
Comments
APAR Information
APAR number
JR31570
Reported component name
WIS DATASTAGE
Reported component ID
5724Q36DS
Reported release
801
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-01-02
Closed date
2009-01-16
Last modified date
2010-12-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
WIS DATASTAGE
Fixed component ID
5724Q36DS
Applicable component levels
R801 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSVSEF","label":"IBM InfoSphere DataStage"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.0.1","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]