IBM Support

JR27605: RDA: ORDER OF PRIMARY KEY ATTRIBUTES FOR AN ENTITY ON A DIAGRAM DOES NOT REFLECT THE ORDER IN THE PROPERTIES VIEW

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • In IBM(R) Rational(R) Data Architect, the order of primary key a
    ttributes for an entity on a diagram does not reflect the order
    in the Properties view.  For non-primary key attributes, the ord
    er on the diagram is the same as the order in the Properties vie
    w.
    Steps to reproduce:
    1.  Create a new logical data model in RDA.
    2.  Add an entity to the model (Entity1).
    3.  Add 3 attributes to the entity (att1, att2, and att3).
    4.  Create a new blank diagram in the model and drag and drop En
    tity1 onto it.
    5.  Select Entity1 on the diagram.
    6.  In the Properties view, click the Attributes tab.
    7.  Select att3 and click the up arrow to change the order of th
    e attributes in the Properties view to be att3, att1, att2.
    8.  Notice that this order is also changed on the diagram (as ex
    pected).
    9.  In the Properties view, make att3 and att1 Primary keys by s
    electing the Primary Key check box for each one.
    10.  Select att1 and click the up arrow to move att1 above att3
    in the Properties view.
    Results:
    The diagram is not updated to reflect this change.
    Workaround:
    Uncheck the Primary Key check box for each of the attributes in
    the Properties view.  Then, check the box again for each attribu
    te in the order that you want them to appear in the diagram.
    

Local fix

Problem summary

  • Fixed in the next release
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    JR27605

  • Reported component name

    RATIONAL DATA A

  • Reported component ID

    5724L6600

  • Reported release

    700

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-10-11

  • Closed date

    2011-06-15

  • Last modified date

    2011-06-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • R750 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSSRXA","label":"Rational Data Architect"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"700","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]