IBM Support

IZ99471: WAREHOUSING OF STH FILES IS SLOW

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PROBLEM DESCRIPTION:
    
    Warehousing of large STH files is slow. Performance may be
    impacted if there is large backload after an outage.
    
    STH upload is slow because the file is read from start on
    redrive. Code needs to remember where it was in the file before
    to avoid re-reading the same data all the data.
    
    RECREATE INSTRUCTIONS:
    N/A
    

Local fix

  • N/A
    

Problem summary

  • Warehousing of short term history files is inefficient for large
    files
    
    
    Warehousing of large short term history files is slow.
    Performance may be impacted if there is a large backlog after an
    outage.
    
    The short term history file upload is slow for large files
    because the file is read from the start rather than where it was
    in the file prior to the outage. This avoids reading the same
    exported rows multiple times in the short term history file.
    

Problem conclusion

  • Short term history file processing was changed to remember the
    last record processed when redriving an export from the previous
    set number of rows exported.
    
    
    The fix for this APAR is included in the following maintenance
    vehicle:
        | fix pack | 6.2.2-TIV-ITM-FP0007
        | release  | 6.2.3-TIV-ITM
    

Temporary fix

Comments

APAR Information

  • APAR number

    IZ99471

  • Reported component name

    TEMS

  • Reported component ID

    5724C04MS

  • Reported release

    622

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-04-27

  • Closed date

    2011-10-24

  • Last modified date

    2012-06-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    OA38199

Fix information

  • Fixed component name

    TEMS

  • Fixed component ID

    5724C04MS