APAR status
Closed as program error.
Error description
Environment: MDM: TWS 8.3 + FP0009 on Windows 2003 (MDM) BDM: TWS 8.3 + FP0009 on Windows 2003 (BDM) FTA: TWS 8.3 + FP0009 on Windows 2003 (FTA01) optman: enSwFaultTol=YES <FTA: 20110114_TWSMERGE.log> 1. mailman started per JnextPlan. 14:28:02 14.01.2011|MAILMAN:AWSBCV085I Starting from host MDM, job number #J7296 2. Autolinks to MDM successfully. 14:28:02 14.01.2011|MAILMAN:AWSBCV029I Attempting to link to MDM. 14:28:02 14.01.2011|MAILMAN:AWSBCV093I Wrote POBox BDM, :My, FM:FTA01 #J8088, TO: LEN:588 ID:1402 14:28:02 14.01.2011|MAILMAN:AWSBCV104I Has linked to MDM using TCP. 14:28:02 14.01.2011|MAILMAN:AWSBCV091I Wrote intercom, :My, FM:FTA01 #J7296, TO:FTA01 LEN:76 ID:0 3. Also links to BDM, per enSwFaultTol=YES, but fails because BDM does not have a new Symphony yet. 14:28:02 14.01.2011|MAILMAN:AWSBCV029I Attempting to link to BDM. : 14:28:02 14.01.2011|MAILMAN:AWSBCV036W Mailman cannot link to the following workstation: BDM because it has an incompatible Symphony file. 14:28:02 14.01.2011|MAILMAN:+ 14:28:02 14.01.2011|MAILMAN:+ AWSBCV035W Mailman was unable to link to workstation: BDM; the messages are written to the PO box. 14:28:02 14.01.2011|MAILMAN:+ 14:28:04 14.01.2011| <BDM: 20110114_TWSMERGE.log> 1. FTA tries to Link to BDM, but unlinks immediately because BDM is not initialized yet. 14:29:25 14.01.2011|FTA01:WRITER:AWSBCW028I Started by MAILMAN/8.3 from FTA01; workstation type: WNT 14:29:25 14.01.2011|FTA01:WRITER:AWSBCW031I Handshake command_type StartMailbox 14:29:25 14.01.2011|FTA01:WRITER:AWSBCW031I Handshake command_type Unlnk 14:29:25 14.01.2011|FTA01:WRITER:AWSBCW032I Mailman has told me to quit, total cpu 0 : 14:29:26 14.01.2011|BATCHMAN:AWSBDY111I Received command MY:WRITER-DOWN for run number -1 workstation FTA01 from workstation BDM 14:29:26 14.01.2011|BATCHMAN:Workstation FTA01 State is being changed: UNSETTING: WRITER : 14:29:26 14.01.2011|BATCHMAN:AWSBDY111I Received command MY:WRITER-DOWN for run number -1 workstation FTA01 from workstation BDM 14:29:26 14.01.2011|BATCHMAN:Workstation FTA01 State is being changed: UNSETTING: WRITER <MDM: 20110114_TWSMERGE.log> 1. FTA FTA01 is linked normally and writer starts on MDM. 14:29:25 14.01.2011|MAILMAN:AWSBCV029I Attempting to link to FTA01. : 14:29:25 14.01.2011|MAILMAN:AWSBCV061I Starting to initialize FTA01 14:29:25 14.01.2011|MAILMAN:AWSBCV055I Finished initializing FTA01 14:29:25 14.01.2011|MAILMAN:AWSBCV091I Wrote intercom, :My, FM:MDM #J5856, TO:MDM LEN:76 ID:0 14:29:25 14.01.2011|MAILMAN:AWSBCT041I Service 2002 started on FTA01 14:29:25 14.01.2011|MAILMAN:AWSBCV104I Has linked to FTA01 using TCP. : 14:29:25 14.01.2011|BATCHMAN:AWSBDY104I Received command MY:LINK for run number 1603 for workstation FTA01 from workstation MDM 14:29:25 14.01.2011|BATCHMAN:Workstation FTA01 State is being changed: LINKED=TCP : 14:29:25 14.01.2011|FTA01:WRITER:AWSBCW028I Started by MAILMAN/8.3 from FTA01; workstation type: WNT : 14:29:25 14.01.2011|FTA01:WRITER:AWSBAT006I The event counter table was successfully filled. Initialization is complete. 14:29:25 14.01.2011|FTA01:WRITER:AWSBCW031I Handshake command_type StartMailbox 2. MDM starts to initialize BDM, BDM and writer starts on MDM. 14:29:25 14.01.2011|MAILMAN:AWSBCV029I Attempting to link to BDM. : 14:29:25 14.01.2011|MAILMAN:AWSBCV061I Starting to initialize BDM 14:29:25 14.01.2011|MAILMAN:AWSBCV055I Finished initializing BDM : 14:29:26 14.01.2011|BDM:WRITER:AWSBCW028I Started by MAILMAN/8.3 from BDM; workstation type: WNT 14:29:26 14.01.2011|BDM:WRITER:AWSBAT001I The event counter is successfully initializing: AWSBAT051I During its initialization, the process copied the records for the event counter table from the version stored in the EventCounter file. 14:29:26 14.01.2011|BDM:WRITER:AWSBAT006I The event counter table was successfully filled. Initialization is complete. 14:29:26 14.01.2011|BDM:WRITER:AWSBCW031I Handshake command_type StartMailbox 3. MDM receives WRITER-UP from MDM. 14:29:28 14.01.2011|BATCHMAN:AWSBDY112I Received command MY:WRITER-UP for run number -1 for workstation FTA01 from workstation MDM. 14:29:28 14.01.2011|BATCHMAN:Workstation FTA01 State is being changed: WRITER 4. MDM receives WRITER-DOWN from BDM and unsets writer. 14:29:28 14.01.2011|BATCHMAN:AWSBDY111I Received command MY:WRITER-DOWN for run number -1 for workstation FTA01 from workstation BDM. 14:29:28 14.01.2011|BATCHMAN:Workstation FTA01 State is being changed: UNSETTING: WRITER Result: On MDM, conman sc shows "FTI J" without "W", although writer is running on MDM. FTA01 1603 WNT FTA 20 0 01/14/11 14:28 FTI J MASTERDM
Local fix
n/a
Problem summary
See Apar Description. This issue is present onl y when enSwFaultTol=YES.
Problem conclusion
This apar will be fixed into 8.5.1-TIV-TWS-F P0002, 8.5-TIV-TWS-FP0003 and 8.4-TIV-TWS-FP0006.
Temporary fix
Comments
APAR Information
APAR number
IZ94316
Reported component name
TIV WRKLD SCHDL
Reported component ID
5698WKB83
Reported release
83T
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-02-02
Closed date
2011-03-04
Last modified date
2011-03-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TIV WRKLD SCHDL
Fixed component ID
5698WKB83
Applicable component levels
R83T PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGSPN","label":"IBM Workload Scheduler"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"83T","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
04 March 2011