IBM Support

IZ91233: EXTRA CLEAR ACA SENT WHILE USING ROUND ROBIN ALGORITHM APPLIES TO AIX 5300-10

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When using the round robin MPIO algorithm, the SCSI disk head
    driver may send out extraneous Clear ACA task management
    commands.  Most storage devices just accept and ignore such
    extra commands.  But if a storage device rejects the extra
    clear ACA (as it is allowed to do per the standards), this
    could result in extra LUN or Target reset commands, which
    could affect I/O throughput.
    

Local fix

Problem summary

  • When using the round robin MPIO algorithm, the SCSI disk head
    driver may send out extraneous Clear ACA task management
    commands.  Most storage devices just accept and ignore such
    extra commands.  But if a storage device rejects the extra
    clear ACA (as it is allowed to do per the standards), this
    could result in extra LUN or Target reset commands, which
    could affect I/O throughput.
    

Problem conclusion

  • Modified the SCSI disk head driver to close a timing window
    that caused the head driver to send multiple Clear ACA
    task management functions for a single check condition.
    

Temporary fix

Comments

  • 5300-10 - use AIX APAR IZ91233
    5300-11 - use AIX APAR IZ91151
    5300-12 - use AIX APAR IZ90693
    6100-03 - use AIX APAR IZ93673
    6100-04 - use AIX APAR IZ93601
    6100-05 - use AIX APAR IZ93420
    6100-06 - use AIX APAR IZ93005
    6100-06 - use AIX APAR IZ85136
    7100-00 - use AIX APAR IZ85504
    

APAR Information

  • APAR number

    IZ91233

  • Reported component name

    AIX 5.3

  • Reported component ID

    5765G0300

  • Reported release

    530

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2010-12-18

  • Closed date

    2010-12-18

  • Last modified date

    2013-04-16

  • APAR is sysrouted FROM one or more of the following:

    IZ85136

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX 5.3

  • Fixed component ID

    5765G0300

Applicable component levels

  • R530 PSY U838237

       UP11/02/23 I 1000

PTF to Fileset Mapping

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11P","label":"APARs - AIX 5.3 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"530","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
16 April 2013