Error description
System crashes when adding more than 32 sites to the configuration files.
Local fix
Separate the config into multiple files so as not to exceed 32 sites perconfig. This block or method requires more than 256 literals.
Problem summary
The Proviso Core Smalltalk puts a limit of 256 literals per function, when configuring a large number of sites in the CUCMConfig.js you can run into this. This is a configuration issue.
Problem conclusion
A second sites file will need to be created and the scripts modified to properly import this second config file. The following TechNote describes this process: TNPM VOIP Cisco IPT Technology Pack CUCMConfig.js file fails with an error over 256 literals when configuring large number of sites
Temporary fix
Comments
APAR Information
APAR number
IZ74774
Reported component name
CISCO IP TELEPH
Reported component ID
5724P66CT
Reported release
43X
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-04-19
Closed date
2010-05-19
Last modified date
2010-06-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CISCO IP TELEPH
Fixed component ID
5724P66CT
Applicable component levels
R43X PSY
UP
[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSHZA","label":"Netcool\/Proviso"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"43X"}]
Document Information
Modified date:
14 December 2020