A fix is available
APAR status
Closed as program error.
Error description
If you link objects created with the V10 C/C++ compiler and use the -bstabcmpct:2 flag, an error message is printed, similar to: ld: 0711-377 STABSTRING ERROR: Symbol table entry xx, object file xxx.o. Type zz has multiple definitions.
Local fix
Problem summary
If you link objects created with the V10 C/C++ compiler and use the -bstabcmpct:2 flag, an error message is printed, similar to: ld: 0711-377 STABSTRING ERROR: Symbol table entry xx, object file xxx.o. Type zz has multiple definitions.
Problem conclusion
Allow some stabstrings to have duplicate definitions if the first definition is a special forward-reference definition.
Temporary fix
Comments
APAR Information
APAR number
IZ73613
Reported component name
AIX 5.3
Reported component ID
5765G0300
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2010-03-29
Closed date
2010-03-29
Last modified date
2013-03-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 5.3
Fixed component ID
5765G0300
Applicable component levels
R530 PSY U832835
UP10/05/14 I 1000
PTF to Fileset Mapping
U832835 bos.rte.bind_cmds 5.3.11.3
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11P","label":"APARs - AIX 5.3 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"530","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: