Fixes are available
APAR status
Closed as program error.
Error description
Need to detect and attempt to recover from out of sequence entries in the node list table. Currently, if a table is not closed properly, verification of the contents is done. This verification code will need to be enhanced to detect out of sequence entries.
Local fix
Problem summary
Symptoms vary, including objects not being distributed correctly, and duplicate insert errors. However, presence of these symptoms doesn't always indicate table corruption. The most reliable way to detect this issue is to apply the fix.
Problem conclusion
During monitoring server startup, if a table was not closed properly during the previous run, as part of the verification process, the monitoring server will check and repair damages from previous unexpected terminations automatically. Because the previous level of the monitoring server could not detect this problem, upgraded environments that have just installed this fix should add the following environment variable to KBBENV during the first run so all tables are checked: KGL_CBTVERIFY=ALWAYS Tables are backed up automatically before repair. For instance, if QA1CNODL needed to be repaired, the following backup files are created in the tables directory first. QA1CNODL.DB.4b1da7fb-1.BAK QA1CNODL.IDX.4b1da7fb-1.BAK The hex number is the UTC timestamp and it matches the RAS1 trace name. This fix does not apply to z/OS, which uses a different facility and doesn't suffer this type of corruption to begin with. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.2.2-TIV-ITM-FP0002
Temporary fix
Comments
APAR Information
APAR number
IZ71237
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
622
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-03-03
Closed date
2010-03-05
Last modified date
2010-05-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
R622 PSY
UP