APAR status
Closed as program error.
Error description
Reading entered in Work Order via the task line on the Actuals tab in Work Order Tracking not updating Asset. Maximo - 6.2.1 Build 156 DB build V600-530 Windows 2003 Weblogic 8.1.4.0. Measurement information entered in the Work Order application on the Plans/Actuals tab, on a task line item, updates the reading for the Measurement Point in Condition Monitroing application, however, in the Assets application if you recall the asset and select Manage Meter Readings History there is no reference to the reading which was entered from the Work Order application. Steps to replicate: Create Asset (11430TEST) Create a Job Plan with this asset (JP11430TST) Create a Meter O-PressureTST with the Type - Gauge, Unit - PSI Create a Condition Monitoring Point, Assign Asset (11430), Assign Meter (O-PressureTST). Upper Warning Limit - 4500 Upper Action - 5000 Lower Warning Limit - 3500 Lower Action Limit - 3200 Upper Limit Job Plan, Lower Limit Job Plan (JP11430TST) Upper Priority 2, Lower Priority 2 Open a new work order, assign Asset, 11430TEST, Assign job plan JP11430TST Approve the work order, then enter on Actuals tab, for one of your tasks a Gauge Meter value (4000) for Measurement Information Save Go back to your Condition Monitoring application and recall the point you created for the Asset 11430TEST, value will be recorded (4000) Go to your Asset (11430TEST), Select Actions Drop Down Menu, select "Manage Meters History"- Characteristics and Gauge Meter Readings is not updated with the gauge meter reading that was entered on the Work Order. Tested and confirmed the behavior. The question is: Should the reading recorded on the Actuals tab be relevant and update to the Asset, as it is recorded against a condition monitoring point? I think it should. Further testing indicated that placing a value in the Measurement Value field without a Measurement Point Value on the Actuals tab in the WOT app also does not show up in the Manage Meter Readings History in the Asset application. It does not show up if a Measurement Point is not entered, either in the aforementioned option or in the Condition Monitoring application as expected. If the Enter Meter Readings option is used in the Work Order Tracking app then the value entered does show up in the Manage Meter Reading History option in the Assets app. Tested the client's scenario in Maximo 5.2 and while the functionality is different, ultimately the reading, entered on the task line on the Actuals tab, was updated on the Measurement tab (which in 6.2.1 is replaced by the Select Actions option Manage Meter Readings History) for the equipment in the Equipment application. It also updated the measurement reading for the point in the Condition Monitoring application. In testing in 5.2 I also noticed that there is no Enter Meter readings option in the Select Actions menu of the WO Tracking application, just another way 5.2 differs from 6.2.1.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Maximo users * **************************************************************** * PROBLEM DESCRIPTION: Fields: assetnum, location, inspector, * * metername, assetid were not saved in * * the measurement table * * * **************************************************************** * RECOMMENDATION: * * * * * * * **************************************************************** READING ENTERED IN WORK ORDER VIA THE TASK LINE ON THE ACTUALS TAB IN WORK ORDER TRACKING NOT
Problem conclusion
Fixed in the FldWOMeasuremtnValue.java, FldWOMeasureData.java and FldWOPointNum.java
Temporary fix
Comments
APAR Information
APAR number
IZ07546
Reported component name
ASSETS
Reported component ID
5724R46AS
Reported release
621
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2007-10-29
Closed date
2007-12-03
Last modified date
2007-12-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
MAXIMO
Fix information
Fixed component name
ASSETS
Fixed component ID
5724R46AS
Applicable component levels
R621 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"621","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date: