IBM Support

IV99213: CRASH WHILE TESTING SNMP TEST BUCKET APPLIES TO AIX 7100-05

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Crash with this stack when running UDP detailed trace and
    MODS:
    
    DB(0)> f pvthread+088800 STACK:  Ý06125624¨udp_input1+0000C4
    (F100050007232E00, F1000B00007589C0,
       F1000B0000EF67C0) Ý06197980¨ipintr_noqueue_post_fw+000A80
    (0000000000000000, F100050007232E00,
       0000000000000000) Ý06198C74¨ipintr_noqueue+0001D4 (??, ??,
    ??) Ý06198E24¨ipintr+0000E4 ()
    Ý00219790¨IPRA.$i_offlevel+000170 (??, ??)
    Ý00219130¨i_softmod+000630 () Ý00237940¨flih_util+000260 ()
    

Local fix

Problem summary

  • Crash with this stack when running UDP detailed trace and
    MODS:
    
    DB(0)> f pvthread+088800 STACK:   06125624 udp_input1+0000C4
    (F100050007232E00, F1000B00007589C0,
       F1000B0000EF67C0)  06197980 ipintr_noqueue_post_fw+000A80
    (0000000000000000, F100050007232E00,
       0000000000000000)  06198C74 ipintr_noqueue+0001D4 (??, ??,
    ??)  06198E24 ipintr+0000E4 ()
     00219790 IPRA.$i_offlevel+000170 (??, ??)
     00219130 i_softmod+000630 ()  00237940 flih_util+000260 ()
    

Problem conclusion

  • Save filtered mbuf flag from mbuf before calling functions that
    might free the mbuf, and use the saved flag in UDP trace calls.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV99213

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-08-22

  • Closed date

    2017-08-22

  • Last modified date

    2018-09-21

  • APAR is sysrouted FROM one or more of the following:

    IV99209

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U870529

       UP17/10/13 I 1000