APAR status
Closed as fixed if next.
Error description
SAS RAID DISK I/O on AIX V7.1 TL3SP9 is much slower than on AIX V7.1 TL3SP1, or after installing APAR IV51289. THe issue is that TCQ depth gets forced to default value of 1. The following dd test shows the issue. The data has to be larger than 1024 MB. # timex dd if=/dev/zero bs=1M count=1000 of=/dev/rtestlv 1000+0 records in 1000+0 records out real 20.16 user 0.00 sys 0.23 For reference, the results of AIX V7.1 TL3 SP1 are # timex dd if=/dev/zero bs=1M count=1000 of=/dev/rtestlv 1000+0 records in 1000+0 records out real 7.80 user 0.00 sys 0.23
Local fix
Problem summary
Corrected problem when reading mode page 20.
Problem conclusion
Temporary fix
Comments
This APAR is being closed FIN. This means that a solution to this APAR is expected to be delivered from IBM in a release (if any) to be available within the next 24 months.
APAR Information
APAR number
IV96987
Reported component name
AIX V7.1
Reported component ID
5765H4000
Reported release
710
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-06-07
Closed date
2017-06-09
Last modified date
2017-06-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11R"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]
Document Information
Modified date: