************************************************************** * USERS AFFECTED: * Systems running the AIX 6100-09 Technology Level or * VIOS 2.2.x.x with * devices.fcp.disk.rte below the 6.1.9.300 level, * devices.pci.77102224.com below the 6.1.9.300 level, * devices.pci.df1000f7.com below the 6.1.9.300 level, * and devices.pciex.df1060e214103404.com below the * 6.1.9.300 level. ************************************************************** * ERROR DESCRIPTION: * On an AIX or VIOS LPAR using a physical Fibre Channel * adapter or Virtual Fibre Channel (NPIV) adapter, with * certain storage devices (see below), if communication * between the LPAR and the storage device is severed and * there are multiple writes to the same block happening at * that time, after the path fails, the driver may retry I/Os * down an alternate path too quickly and data may be written * to the device in a different order than it is completed to * the application, possibly resulting in undetected data loss. * * We have seen this, for example, when testing a link drop by * pulling FC cables between LPARs and storage. * * We have seen this issue occur when testing the following * storage devices: * - IBM Flash Systems * - IBM San Volume Controller (SVC) with caching turned off * for the volume * - IBM Storwize family products with caching turned off * for the volume * * This issue CANNOT occur with the following storage devices: * - IBM DS8000 series * - IBM San Volume Controller (SVC) with caching turned on * for the volume * - IBM Storwize family products with caching turned on * for the volume * - IBM XIV family * - EMC Symmetrix family * * Storage devices not specifically mentioned above should be * assumed to be exposed to this problem. * * This issue also cannot occur when reserve_policy for the * disks is set to single_path. ************************************************************** * RECOMMENDATION: * Install APAR IV96553. * Prior to fix availability, an interim fix is available from * either * ftp://aix.software.ibm.com/aix/ifixes/iv96553/ * https://aix.software.ibm.com/aix/ifixes/iv96553/ * Installation of the ifix requires a reboot. **************************************************************
Local fix
If possible, changing the reserve_policy to single_path will avoid this problem because a LUN RESET will be triggered when switching paths.
Problem summary
On an AIX or VIOS LPAR using certain Fibre Channel adapters, if communication between the LPAR and the storage device is severed and there are multiple writes to the same block happening at that time, after the path fails, the driver may retry I/Os down an alternate path too quickly, and data may be written to the device in a different order than it is completed to the application, possibly resulting in undetected data loss.
Problem conclusion
After certain FC adapter errors, where the host does not know if a particular aborted command may still be completed by the storage, the host performs additional recovery by sending LUN RESET to ensure all aborted commands are flushed from the storage.
Temporary fix
********* * HIPER * *********
Comments
APAR Information
APAR number
IV96553
Reported component name
AIX 610 STD EDI
Reported component ID
5765G6200
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Submitted date
2017-05-24
Closed date
2017-05-24
Last modified date
2018-09-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 610 STD EDI
Fixed component ID
5765G6200
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11Q","label":"AIX 6.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSMV87","label":"AIX 6.1 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSMVAX","label":"AIX Express Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSAUMY","label":"IBM AIX Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11Q","label":"AIX 6.1 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11R","label":"APARs - AIX 7.1 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"610","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]
Document Information
Modified date:
17 December 2021