IBM Support

IV91028: TRAP IN VIOENT_INIT_LS_TIMER

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When poll_uplink=yes is set, the system will crash with
    the IAR in vioent_init_ls_timer.
    

Local fix

  • Turning poll_uplink to no avoids the issue until a fix
    can be applied.
    

Problem summary

  • A compiler option is used with the vioentdd driver to
    instrument a number of runtime checks.  These checks
    are hit regularly by vioent_init_ls_timer(), which is
    executed when poll_uplink=yes.
    

Problem conclusion

  • For now remove the compiler option to avoid the asserts.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV91028

  • Reported component name

    AIX V7.1

  • Reported component ID

    5765H4000

  • Reported release

    710

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-11-25

  • Closed date

    2016-11-25

  • Last modified date

    2017-10-13

  • APAR is sysrouted FROM one or more of the following:

    IV91004

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.1

  • Fixed component ID

    5765H4000

Applicable component levels

  • R710 PSY U870549

       UP17/10/13 I 1000

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11R"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"710","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]