IBM Support

IV89868: TR 7610 - THE SYSTEM INDICATES THAT THE METER READINGS WERE EXPORTED. BUT IN THE ERROR COUNTS IT SHOWS A NUMBER 1.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PROBLEM:
    
    Customer found out that there is a difference on the
    functionality regarding the application PLUSTLOGS
    (Registros(Tr)) located inside the ASSET module
    
    comparing the same functionality between MAXIMO 7.1 and MAXIMO
    7.6:
    
    In 7.1, whenever we try to add a new record in the PLUSTLOGS
    application for an asset, by default the system takes the last
    meter reading for the asset and
    
    the user only have to enter the new reading, and the system
    calculates the delta between the two readings.
    
    Now, in MAXIMO 7.6, whenever we try to enter a new record for
    an asset, by default the system takes the cumulative readings
    for the asset and puts that
    
    value in the inicial reading field, not the last reading as in
    7.1, which might be lower that the cumulative reading due to
    the meter can have a rollover point,
    so if the user enters a higher to the cumulative this can be
    higher than the rollover value and a message is displayed
    
    PERFORMANCE ISSUE: NO
    
    STEPS TO REPRODUCE:
    
    1) Go to Asset - Meter application and create 2 meters follow,
    if the meters are created, just change it accordingly:
    
     a) ODOMETRO:
    
    - Metername: ODOMETRO
    - Metertype: CONTINUOS
    - Readingtype: ACTUAL
    - Domainid: null
    - Measureunit : KM - kilometer (it must exist, otherwise
    conversion units and measures will be needed)
    
     b) HISTORICO:
    
    - Metername: HISTORICO
    - Metertype: CONTINUOUS
    - Readingtype: ACTUAL
    - Domainid: null
    - Measureunit : null
    
    2) Create the asset from Asset(Tr) application, only consider
    filling the required fields
    
    3) Add the 2 meters created in step 1. In the meter tab, click
    on new row and add one meter at a time
    
     a) ODOMETRO:
    
    On the Continuous meter Details section, enter the following
    data for Odometro meter:
    - Average Calculation Method: STATIC
    - Average Units/day: 1500
    - Initial Lif to Date: 629623
    - Initial Reading: 0
    - Rollover: 999999
    - Reading Type: Actual
    - Day Limit: 2000
    
     b) HISTORICO
    On the Continuous meter Details section, enter the following
    data for Historico meter:
    - Average Calculation Method: SLIDING-READINGS
    - Sliding Window Size: 12
    - Initial Lif to Date: 2999999
    - Initial Reading: 0
    - Rollover: 999999
    - Reading Type: Actual
    - Day Limit: null
    
    Save the asset record
    
    Change asset status to operating
    
    4) Go to Asset - Logs(Tr) application and create a new Log(Tr)
    record
    
    5) Go to Trip Detail section
    Trip number: 1
    Fuel Quantity: 10
    Meter units: KMS
    
    6) Go to Log Meter Readings and enter meter reading for
    Odometro meter
    Go to Meter reading Logs, click on New Row and enter the
    following data.
    - Trip number: 1
    - Meter: Odometro
    - Meter Start: 2.999.999,00
    - Meter Delta: null
    - Meter Units: KM
    - Reading date: Actual
    - Meter End: 3000100
    
    Save the record
    
    7) Select Action: Export meter readings In the popup window
    select Ignore Warnings
    Select the corresponding meter (ODOMETRO)
    Click on Export button
    
    CURRENT ERRONEOUS RESULT:
    The system indicates that the meter readings were exported. But
    in the Error counts it shows a number 1.
    BMXAA7095E - THE ENTERED VALUE 3.000.100,00 IS NOT VALID. ENTER
    A VALID DECIMAL VALUE
    
    EXPECTED RESULT:
    Export meter readings success
    
    ENVIRONMENT (SYSTEM INFO):
    Linux 2.6.32-431.el6.x86-64
    IBM WebSphere Application Server 8.5.5.3
    Oracle 12.1 (Oracle Database 12c Enterprise Edition Release
    12.1.0.2.0 - 64bit Production With the Partitioning, OLAP,
    Advanced Analytics and Real
    
    Application Testing options)
    
    Tivoli process automation engine 7.6.0.2 Build 20150903-2113
    DBBuild V7602-31
    IBM TPAE Integration Framework 7.6.0.2 Build 20150901-2100
    DBBuild V7602-05
    IBM Maximo for Transportation 7.6.1.0 Build 20150902-2035
    DBBuild V7610-03
    IBM Maximo Asset Management 7.6.0.2 Build 20150903-2113 DBBuild
    V7601-01
    

Local fix

  • na
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All Users that use Maximo Transportation 7.6.1.0             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * THE SYSTEM INDICATES THAT THE METER READINGS WERE            *
    * EXPORTED. BUT IN THE ERROR COUNTS IT SHOWS A NUMBER 1.       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fix incorrect Checking  and define correct locale
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV89868

  • Reported component name

    MX TRANSPORTATI

  • Reported component ID

    5724R5500

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-10-10

  • Closed date

    2016-11-28

  • Last modified date

    2024-10-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    MX TRANSPORTATI

  • Fixed component ID

    5724R5500

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSLL9Z","label":"Maximo for Transportation"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date: