APAR status
Closed as program error.
Error description
PROBLEM: Customer found out that there is a difference on the functionality regarding the application PLUSTLOGS (Registros(Tr)) located inside the ASSET module comparing the same functionality between MAXIMO 7.1 and MAXIMO 7.6: In 7.1, whenever we try to add a new record in the PLUSTLOGS application for an asset, by default the system takes the last meter reading for the asset and the user only have to enter the new reading, and the system calculates the delta between the two readings. Now, in MAXIMO 7.6, whenever we try to enter a new record for an asset, by default the system takes the cumulative readings for the asset and puts that value in the inicial reading field, not the last reading as in 7.1, which might be lower that the cumulative reading due to the meter can have a rollover point, so if the user enters a higher to the cumulative this can be higher than the rollover value and a message is displayed PERFORMANCE ISSUE: NO STEPS TO REPRODUCE: 1) Go to Asset - Meter application and create 2 meters follow, if the meters are created, just change it accordingly: a) ODOMETRO: - Metername: ODOMETRO - Metertype: CONTINUOS - Readingtype: ACTUAL - Domainid: null - Measureunit : KM - kilometer (it must exist, otherwise conversion units and measures will be needed) b) HISTORICO: - Metername: HISTORICO - Metertype: CONTINUOUS - Readingtype: ACTUAL - Domainid: null - Measureunit : null 2) Create the asset from Asset(Tr) application, only consider filling the required fields 3) Add the 2 meters created in step 1. In the meter tab, click on new row and add one meter at a time a) ODOMETRO: On the Continuous meter Details section, enter the following data for Odometro meter: - Average Calculation Method: STATIC - Average Units/day: 1500 - Initial Lif to Date: 629623 - Initial Reading: 0 - Rollover: 999999 - Reading Type: Actual - Day Limit: 2000 b) HISTORICO On the Continuous meter Details section, enter the following data for Historico meter: - Average Calculation Method: SLIDING-READINGS - Sliding Window Size: 12 - Initial Lif to Date: 2999999 - Initial Reading: 0 - Rollover: 999999 - Reading Type: Actual - Day Limit: null Save the asset record Change asset status to operating 4) Go to Asset - Logs(Tr) application and create a new Log(Tr) record 5) Go to Trip Detail section Trip number: 1 Fuel Quantity: 10 Meter units: KMS 6) Go to Log Meter Readings and enter meter reading for Odometro meter Go to Meter reading Logs, click on New Row and enter the following data. - Trip number: 1 - Meter: Odometro - Meter Start: 2.999.999,00 - Meter Delta: null - Meter Units: KM - Reading date: Actual - Meter End: 3000100 Save the record 7) Select Action: Export meter readings In the popup window select Ignore Warnings Select the corresponding meter (ODOMETRO) Click on Export button CURRENT ERRONEOUS RESULT: The system indicates that the meter readings were exported. But in the Error counts it shows a number 1. BMXAA7095E - THE ENTERED VALUE 3.000.100,00 IS NOT VALID. ENTER A VALID DECIMAL VALUE EXPECTED RESULT: Export meter readings success ENVIRONMENT (SYSTEM INFO): Linux 2.6.32-431.el6.x86-64 IBM WebSphere Application Server 8.5.5.3 Oracle 12.1 (Oracle Database 12c Enterprise Edition Release 12.1.0.2.0 - 64bit Production With the Partitioning, OLAP, Advanced Analytics and Real Application Testing options) Tivoli process automation engine 7.6.0.2 Build 20150903-2113 DBBuild V7602-31 IBM TPAE Integration Framework 7.6.0.2 Build 20150901-2100 DBBuild V7602-05 IBM Maximo for Transportation 7.6.1.0 Build 20150902-2035 DBBuild V7610-03 IBM Maximo Asset Management 7.6.0.2 Build 20150903-2113 DBBuild V7601-01
Local fix
na
Problem summary
**************************************************************** * USERS AFFECTED: * * All Users that use Maximo Transportation 7.6.1.0 * **************************************************************** * PROBLEM DESCRIPTION: * * THE SYSTEM INDICATES THAT THE METER READINGS WERE * * EXPORTED. BUT IN THE ERROR COUNTS IT SHOWS A NUMBER 1. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fix incorrect Checking and define correct locale
Temporary fix
Comments
APAR Information
APAR number
IV89868
Reported component name
MX TRANSPORTATI
Reported component ID
5724R5500
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-10-10
Closed date
2016-11-28
Last modified date
2024-10-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MX TRANSPORTATI
Fixed component ID
5724R5500
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSLL9Z","label":"Maximo for Transportation"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
31 October 2024