IBM Support

IV84379: BOS.ADT.INCLUDE FILESET MISSING J2_SYNC.H AT 7100-04-01 APPLIES TO AIX 7200-01

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • While compiling a program which includes j2_inode.h file
    can get following error message:
    ---------------------------------
    "/usr/include/j2/j2_inode.h", line 55.10: 1506-296 (S)
    #include file
    <j2/j2_sync.h> not
    found..............................................
    ---------------------------------
    
    The j2_inode.h file has a line including j2_sync.h:
    #include <j2/j2_sync.h>
    
    However j2/j2_sync.h file is not available on the
    machine.
    
    The j2_inode.h has been changed to include the field
    ...
    j2SyncData_t  *i_syncData;    /* 8: control point for
    sync */
    ...
    in its mntInode structure.
    The j2SyncData_t definition is in the j2_sync.h file that
     is missing.
    

Local fix

  • Using the bos.adt.7.1.3.45 fileset verision of j2_inode.h
    will make the compile succeed since the new field is not
    in the
    earlier version.
    

Problem summary

  • Since 71 TL04, j2_inode.h includes a new header file that is
    not shipped. Programs that include j2_inode.h may now fail to
    compile.
    

Problem conclusion

  • Removed the new #include line, and added a nominal definition
    of the necessary datatype to j2_inode.h
    

Temporary fix

Comments

  • 7200-01 - use AIX APAR IV84379
    

APAR Information

  • APAR number

    IV84379

  • Reported component name

    AIX V7.2

  • Reported component ID

    5765CD200

  • Reported release

    720

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Submitted date

    2016-05-03

  • Closed date

    2016-05-03

  • Last modified date

    2016-12-09

  • APAR is sysrouted FROM one or more of the following:

    IV84218

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    AIX V7.2

  • Fixed component ID

    5765CD200

Applicable component levels

  • R720 PSY U875194

       UP16/12/09 I 1000

[{"Business Unit":{"code":"BU070","label":"IBM Infrastructure"},"Product":{"code":"SSVEF8","label":"AIX 7.2 Enterprise Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB68","label":"Power HW"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SG11S","label":"AIX 7.2 HIPERS, APARs and Fixes"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"720","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}}]

Document Information

Modified date: