A fix is available
APAR status
Closed as program error.
Error description
In some time zones, the time stamp in the header of KINCINFO output is off by one hour of that shown at the system level. This symptom is innocuous (it does not affect the function of ITM). See also APAR IV53978. Approver Initials: TR
Local fix
None. The symptom is innocuous.
Problem summary
For some locales that do not recognize daylight saving time, the reported current time in the KinCInfo header may be off by one hour. For some locales that do not recognize daylight saving time, the reported current time in the KinCInfo header may be off by one hour. Locale developed time is performed by an IBM Tivoli Monitoring call to NLS code which may fail for locales that do not recognize daylight saving time.
Problem conclusion
The code was modified to process all times using Microsoft CTime API which is locale compliant. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.3.0-TIV-ITM-FP0007
Temporary fix
The time can be ignored as it is information only and does not effect the code execution.
Comments
APAR Information
APAR number
IV82690
Reported component name
OMEG DIST INSTA
Reported component ID
5608A41CI
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-03-14
Closed date
2016-11-18
Last modified date
2017-01-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
OMEG DIST INSTA
Fixed component ID
5608A41CI
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: