APAR status
Closed as program error.
Error description
Error Message: This problem can manifest itself in many different ways. . Stack Trace: N/A . This problem can only occur if auto-SIMD is enabled on either the z13 platform or POWER 7 or later platforms.
Local fix
-Xjit:disableAutoSIMD Note that this may affect performance.
Problem summary
While trying to transform a loop so that it uses SIMD instructions, the JIT compiler encountered an error condition and left the loop only partially transformed.
Problem conclusion
The JIT compiler has been updated to eliminate possible error conditions during the SIMD transformation phase. In addition, if such error still occurs we enforce compilation failure so that the error can be detected earlier. . This APAR will be fixed in the following Java Releases: 8 SR2 (8.0.2.0) . Contact your IBM Product's Service Team for these Service Refreshes and Fix Packs. For those running stand-alone, information about the available Service Refreshes and Fix Packs can be found at: https://www.ibm.com/developerworks/java/jdk/
Temporary fix
Comments
APAR Information
APAR number
IV78059
Reported component name
JIT
Reported component ID
620700124
Reported release
130
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2015-10-14
Closed date
2015-10-14
Last modified date
2015-10-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
JIT
Fixed component ID
620700124
Applicable component levels
R130 PSY
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSC9HBA","label":"Just In Time (JIT) Compiler"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 October 2015