IBM Support

IV73136: REMOTE CONTROL FIXLETS CAN FAIL WITH RETURN CODE 3010

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • Actions to install the fixlet "Deploy IBM Endpoint Manager for
    Remote
    Control Target for Windows"  from the "Site Tivoli Remote
    Control" ID 22 is failing
    They fail at the line continue if exit code of action =0
    
    The return code of the install on the previous line is 3010
    (restart needed)
    

Local fix

Problem summary

  • Users affected
    
    The following fixlets are affected:
    1 Deploy IBM Endpoint Manager for Remote control Controller for
    Windows
    10 Deploy IBM Endpoint Manager for Remote control Controller for
    Linux
    18 Deploy IBM Endpoint Manager for Remote control Target for
    Linux
    22 Deploy IBM Endpoint Manager for Remote control Target for
    Windows
    29 Deploy IBM Endpoint Manager for Remote control CLI Tools for
    Windows
    30 Deploy IBM Endpoint Manager for Remote control CLI Tools for
    Linux
    33 Deploy IBM Endpoint Manager for Remote control Gateway for
    Windows
    34 Deploy IBM Endpoint Manager for Remote control Gateway for
    Linux
    37 Deploy IBM Endpoint Manager for Remote control Broker for
    Windows
    38 Deploy IBM Endpoint Manager for Remote control Broker for
    Linux
    48 Updated IBM Endpoint Manager for Remote control Controller
    for Windows is now available!
    49 Updated IBM Endpoint Manager for Remote control Gateway for
    Linux is now available!
    50 Updated IBM Endpoint Manager for Remote control Target for
    Windows is now available!
    51 Updated IBM Endpoint Manager for Remote control Controller
    for Linux is now available!
    52 Updated IBM Endpoint Manager for Remote control Broker for
    Windows is now available!
    53 Updated IBM Endpoint Manager for Remote control CLI tools for
    Linux is now available!
    54 Updated IBM Endpoint Manager for Remote control Broker for
    Linux is now available!
    55 Updated IBM Endpoint Manager for Remote control Target for
    Linux is now available!
    56 Updated IBM Endpoint Manager for Remote control Gateway for
    Windows is now available!
    57 Updated IBM Endpoint Manager for Remote control CLI Tools for
    Windows is now available!
    
    Problem Summary
    On endpoints where a reboot is pending after the installation of
    a patch or upgrade not related to IBM Endpoint Manager for
    Remote Control, the deployment or update of a Remote Control
    component can result in a return code 3010 from Windows
    Installer. This causes the fixlet to be reported as failed. The
    3010 return code from Windows Installer is not an error, the
    Remote Control installation or upgrade did complete
    successfully. The return code indicates that a previous package
    or patch needs a reboot to complete its installation.
    
    All fixlets were updated to check for the 3010 return code and
    allow the actionscript to continue.
    

Problem conclusion

  • The fix ix published on remote control site 33.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV73136

  • Reported component name

    TIV EP MGR REM

  • Reported component ID

    5725C43RC

  • Reported release

    900

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-05-11

  • Closed date

    2015-06-18

  • Last modified date

    2015-06-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":null,"label":null},"Product":{"code":"SSBQVS","label":"Tivoli Endpoint Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"900","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: