Error description
Situations which operate on two or more attribute groups can cause an ambiguity in the generated TEC event classname for forwarded events due to how the event data is processed. Approver Initials: BG
Local fix
No workaround available.
Problem summary
Forwarded events do not always have the correct event class name. When situations use multiple attribute groups, the event class name for the forwarded event may be determined incorrectly.
Problem conclusion
The code has been changed to properly determine the event class name when an event is forwarded, except for case where a situation includes Local_Time or Universal_Time attributes in the Formula. For the exception cases of Local_Time or Universal_Time attributes, the rule for defining Situations that include Local_Time or Universal_Time attributes in Situation's Formula is : Never create a situation where user adds first 'condition' against a Local_Time or Universal_Time attribute. Here are two example Siuation Formulas (predicates), the first shows the undesired order in Formula definition, the latter shows the desired order in Formula definition, yet the two situations monitor the same issue. SitName:TimeFirst_sit Predicate: *IF *VALUE Local_Time.Hours *GT 09 *AND *VALUE NT_Process_64.Process_Name *EQ firefox SitName:NontimeFirst_sit Predicate: *IF *VALUE NT_Process_64.Process_Name *EQ firefox *AND *VALUE Local_Time.Hours *GT 09 Of course, if the only Attribute Groups in a Situation's Formula are Local_Time and/or Universal_Time, the exception rule does not matter. The fix for this APAR is contained in the following maintenance packages: | fix pack | 6.3.0-TIV-ITM-FP0007
Temporary fix
Comments
APAR Information
APAR number
IV71275
Reported component name
TEMS
Reported component ID
5724C04MS
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-03-20
Closed date
2016-04-25
Last modified date
2017-01-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
TEMS
Fixed component ID
5724C04MS
Applicable component levels
R630 PSY
UP