IV70972: ON Z/OS, GPR15 MAY BE CLOBBERED WHEN THE JAVA VM REDUCES THE SIZ E OF ITS OBJECT HEAP

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Error Message: N/A
    .
    Stack Trace: N/A
    .
    

Local fix

Problem summary

  • The problem affects both the 31 and the 64-bit builds.The
    problem can only be observed if the Java VM attempts to reduce
    the size of its object heap, which is not a very common
    occurrence. If it does try to do so, it is possible the value of
    the GPR15 register will be clobbered by the routine it uses to
    reduce the size of the heap. If this problem is observed, it
    will likely cause failures on the logic of the internal function
    used to reduce the size of the heap. It is undefined what the
    customer would see as a result. A wide range of potential
    problems can arise from this incorrect behavior.
    

Problem conclusion

  • The code was fixed in order to make sure the value of GPR15 is
    properly saved and restored.
    .
    This APAR will be fixed in the following Java Releases:
       6 R1 SR8 FP4   (6.1.8.4)
       7    SR9       (7.0.9.0)
       7 R1 SR3       (7.1.3.0)
    .
    Contact your IBM Product's Service Team for these Service
    Refreshes and Fix Packs.
    For those running stand-alone, information about the Service
    Refreshes and Fix Packs can be found at:
               https://www.ibm.com/developerworks/java/jdk/
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV70972

  • Reported component name

    J9 COMMON CODE

  • Reported component ID

    620700127

  • Reported release

    260

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-03-12

  • Closed date

    2015-03-12

  • Last modified date

    2015-03-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    J9 COMMON CODE

  • Fixed component ID

    620700127

Applicable component levels

  • R260 PSY

       UP

  • R270 PSY

       UP