IBM Support

IV59891: IBM MQ 7.1 or 7.5 dspmqtrc writes out incorrect time stamps when formatting 7.0.1 trace files

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The time stamps on each line of trace are incorrect. This
    happens only when using the "dspmqtrc" trace formatter from a
    WebSphere MQ 7.1 or 7.5 installation to format traces
    originating from previous versions (example : 7.0.1).
    
    This is example incorrect output from the trace header. Notice
    that the time stamp in the left-hand column is very different
    from the time stamps stored near the ends of these lines. The
    time stamps near the ends of the lines are correct.
    01:30:15.556889 15322.1 UTC Date : 02/07/2014 Time :
    12:49:37.890963
    01:30:15.556897 15322.1 Local Date : 02/07/2014 Time :
    13:49:37.890963 CET
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    Users of trace with IBM MQ on distributed platforms.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    There was an integer overflow in the arithmetic being used to
    calculate the time stamp.
    
    However, the data on each line after the time stamp is correct.
    

Problem conclusion

  • The integer overflow problem has been corrected. This APAR is
    being used to deliver the described fix, and other minor fixes
    in IBM MQ trace and the dspmqtrc program.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v7.0       7.0.1.13
    v7.1       7.1.0.6
    v7.5       7.5.0.5
    v8.0       8.0.0.1
    
    The latest available maintenance can be obtained from
    'WebSphere MQ Recommended Fixes'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006037
    
    If the maintenance level is not yet available information on
    its planned availability can be found in 'WebSphere MQ
    Planned Maintenance Release Dates'
    http://www-1.ibm.com/support/docview.wss?rs=171&uid=swg27006309
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV59891

  • Reported component name

    WMQ AIX V7

  • Reported component ID

    5724H7221

  • Reported release

    701

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-04-29

  • Closed date

    2014-06-09

  • Last modified date

    2014-06-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WMQ AIX V7

  • Fixed component ID

    5724H7221

Applicable component levels

  • R701 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDEZSF","label":"IBM WebSphere MQ Managed File Transfer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: