IBM Support

IV59513: ZEDC HARDWARE COMPRESSES DATA EVEN WHEN COMPRESSION LEVEL IS SET TO ZERO ON Z/OS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Error Message: When running Java application on zEC12 server
    with zEDC hardware compression it produces different results
    when java.util.zip.Deflater.setLevel(0) is set compared to
    software compression.  The API setlevel(0) means NO COMPRESSION.
     With zEDC hardware compression the data is compressesd, while
    it is not compressed with software compression.
    .
    Stack Trace: N/A
    .
    

Local fix

Problem summary

  • The problem is caused because zEDC Express hardware compression
    does not consider compression level zero and it compresses the
    data.
    

Problem conclusion

  • This APAR will be fixed in the following Java Releases:
       7 R1 SR1       (7.1.1.0)
       7    SR7       (7.0.7.0)
    .
    The zEDC code in the z/OS JDK has been updated to fallback to
    software compression when compression level is set to ZERO. This
    ensures that the data is not compressed when compression level
    is set to ZERO.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV59513

  • Reported component name

    JAVA CLASS LIBS

  • Reported component ID

    620700130

  • Reported release

    700

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-04-18

  • Closed date

    2014-04-18

  • Last modified date

    2014-04-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    JAVA CLASS LIBS

  • Fixed component ID

    620700130

Applicable component levels

  • R700 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date: