Error description

  • There is an issue in OOTB CU Estimating process.
    All versions associated to the Estimate Request are deleted
    when status
    of Estimate Request is changed from Open to synonym of Open
    (custom
    value).
    STEPS:
    A. Steps to set up Domain (Prerequisites for replicating Issue)
    1. Go to System Configuration -> Platform Configuration ->
    Domains
    2. Get the record for domain  PLUSDRQSTSTATUS
    3. Add new Synonym Value in the domain
    4 Click New Row, specify Internal Value as  OPEN ; specify
    Value as any value, say  RTAPPR
    5 Click OK
    6 Save the record
    B. Steps to Replicate Issue
    1. In the CU Estimating (T&D) application, click New Estimate
    Request
    1002
    2. Set Estimate Request type as JOB
    3. Save the Estimate Request
    4. On the Versions tab, Create Estimate Version of a request,
    specify
    the version information
    5. Specify an Estimate Version, Estimate Type, Estimator, Work
    Group
    and Storeroom if empty
    6. Save the Estimate Request
    7. On the Stations tab, click New Station.
    8. Enter the Station name and Description
    9. Save the Estimate Request
    10. On the Compatible Units tab, insert a row.
    11. Specify the Compatible Unit name or search the CU Library by
    classification or by attribute. The active version of the
    compatible
    unit is added.
    12. Save the Estimate Request
    13. Perform Estimation on Version by selecting action ->
     Perform
    Estimation
    14. Change Estimate Request status to synonym of  OPEN
    (e.g.
    RTAPPR)
    15. All versions associated to Estimate Requests are deleted
    16. The issue appears even when Version is not estimated and
    Request is
    moved from OPEN to synonym of OPEN. All versions associated to
    Estimate
    Requests are deleted
    This issue seems to be the same as IZ77883 which has been
    addressed in Utilities 7.1
    

Local fix

  • n/a
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users that use Maximo for Utilities 7.5.0.1              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * UNABLE TO USE SYNONYM STATUSES IN CUE                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * N/A                                                          *
    ****************************************************************
    

Problem conclusion

  • MboSet rest condition was changed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV55740

  • Reported component name

    MAXIMO UTILITIE

  • Reported component ID

    5724R5600

  • Reported release

    750

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-02-20

  • Closed date

    2014-03-13

  • Last modified date

    2014-03-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • UTIL
    

Fix information

  • Fixed component name

    MAXIMO UTILITIE

  • Fixed component ID

    5724R5600

Applicable component levels

  • R750 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLLAM","label":"Maximo for Utilities"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"750","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
29 September 2021