APAR status
Closed as fixed if next.
Error description
TEM - OSD, TEM 9077 and OSD 7.1.1.12 Customer is trying to capture a Windows 8 64bit reference machine. This machine has been installed from TEM OSd using a profile that has been created from a preloaded Win 8 image. After that customer customized this reference machine installing additional softwares but trying to clone it the capture fails during sysprep. Looking in the BFErrorDetection-stage1.log there is the following error: A <ERR> Stopping Web extension Unable to find the boot partition RbAgent command rad-temsetcounter has failed [AGT:4086]
Local fix
Create a 3.2 bundle
Problem summary
This issue will be addressed in version 3.3 of IEM OSD. Availability January 2014.
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
IV51071
Reported component name
TIV EP MG OS DE
Reported component ID
5725C43OS
Reported release
900
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-10-22
Closed date
2013-11-12
Last modified date
2013-11-12
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
R900 PSY
UP
[{"Business Unit":{"code":null,"label":null},"Product":{"code":"SSBQVS","label":"Tivoli Endpoint Manager"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"900","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
12 November 2013