Error description
PM Status: Populate Stop Date on INACTIVE Option Environment Maximo 7.5.0.1 for windows 2008 Description: PM Status: Populate Stop Date on INACTIVE Option is not working. PMChangestatus Problem PM Status: Populate Stop Date on INACTIVE Option is not working. Test case Step 1. Creating a pm in overdue (PM: 1106). The BDI will not create a workorder because the "Active Date Reviewed" is not checked. Is Ok. Step 2. Change pm Status to "INACTIVE" Preventive Maintenance Application ' Change Status. Checkbox "Populate Stop Date on INACTIVE" is checked. This assumes that the field PM. PLUSASTOPDATE is filled with the sysdate so the BDI should not "re-activates" the pm. Click "OK" and save the PM. After running a query on the pm the it appeared that the PM is set to "INACTIVE" but the PLUSASTOPDATE is null Query: "select pmnum, description,status,PLUSASTOPDATE from pm where pmnum = '1106';" Result: Step 3: Running the BDI Asset ' View ' Maintenance Plan PM "1106" is not visible because it is set to "INACTIVE". When running the BDI a Workorder is created and the PM is listed again on the "Maintenance Plan" tab. This should not happen. The PM needs to stay inactive. eds to stay inactive. Cause The "Database Configuration" application shows the class: "psdi.app.pm.virtual.PMChangeStatusSet" on the "PMCHANGESTATUS" object. Also a field class is set on "STATUS". "psdi.app.pm.virtual.FldPMChangeStatus" "PLUSA" Classes In Eclipse it appeared that there is a class "psdi.plusa.app.pm.virtual.PlusAPMChangeStatusSet" class which extends "psdi.app.pm.virtual.PMChangeStatusSet". The same for field "STATUS". "psdi.plusa.app.pm.virtual.PlusAFldPMChangeStatus" extends "psdi.app.pm.virtual.FldPMChangeStatus". Step 4. Changing the classes on object "PMCHANGESTATUS" Original classes: psdi.app.pm.virtual.PMChangeStatusSet psdi.app.pm.virtual.FldPMChangeStatus Replaced by: psdi.plusa.app.pm.virtual.PlusAPMChangeStatusSet psdi.plusa.app.pm.virtual.PlusAFldPMChangeStatus Step 5. Test Again After a same test the PM.PLUSASTOPDATE is now filled with sysdate when the pm status is changed "INACTIVE". When running the BDI no workorder is generated and the pm is not "re-activated". Now it is working as aspected. Solution Changing the classes on object "PMCHANGESTATUS" as described at step 4. ACM Dev instructed for APAR creation: ACM DEV have identified that there is some missing information from the ACM product xml file which is the root of the reported problem. Raisinge this APAR so that ACM Dev can add the missing information and provide as a hotfix.
Local fix
Dev to fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Maximo ACM Preventive Maintenance application. * **************************************************************** * PROBLEM DESCRIPTION: * * When the status of a PM is changed to INACTIVE and the * * option "Populate Stop Date on INACTIVE" is checked then the * * system fails to populate the Stop Date. * **************************************************************** * RECOMMENDATION: * * Install the hotfix to rectify this problem. * **************************************************************** Missing lines from the ACM product xml file caused the class extensions which implement this functionality to be lost when updatedb is run.
Problem conclusion
Missing class extensions added to aviation.xml to resolve this isssue. The fix for this APAR is contained in the following maintenance package: | release\fix pack | Interim Fix for Release 750 Maximo ACM
Temporary fix
Comments
APAR Information
APAR number
IV34527
Reported component name
PREVENTIVE MAIN
Reported component ID
5724R46PM
Reported release
750
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-01-11
Closed date
2013-01-31
Last modified date
2013-01-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
MAXIMO
Fix information
Fixed component name
PREVENTIVE MAIN
Fixed component ID
5724R46PM
Applicable component levels
R750 PSY
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCHPN7","label":"Prev Maint"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"750","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
31 January 2013