A fix is available
APAR status
Closed as program error.
Error description
If the button "Related Processes" is clicked for Process Instances or the button "Instances" is clicked for Process Templates an error is displayed: "CWWBQ0002E: One or more of the following attributes in the select list are invalid for the IBM.BPCE_PI_ALL query table: topLevelProcessInstanceName, processTemplateDisplayName, parentProcessInstanceName, executionState, name, startTime, . Allowed values are PI_NAME, PT_NAME, PT_VALID_FROM, PI_STATE, PI_STARTED, PI_PARENT_NAME, PI_TOP_LEVEL_NAME, PI_PIID, PI_PTID, PI_PARENT_PIID, PI_TOP_LEVEL_PIID, PT_DISPLAY_NAME, WI.WSID, WI.OWNER_ID, WI.GROUP_NAME, WI.EVERYBODY, WI.REASON, .
Local fix
n/a
Problem summary
Problem Description: If the button "Related Processes" is clicked for Process Instances or the button "Instances" is clicked for Process Templates an error is displayed. Problem Summary: The error message is: "CWWBQ0002E: One or more of the following attributes in the select list are invalid for the IBM.BPCE_PI_ALL query table: topLevelProcessInstanceName, processTemplateDisplayName, parentProcessInstanceName, executionState, name, startTime, . Allowed values are PI_NAME, PT_NAME, PT_VALID_FROM, PI_STATE, PI_STARTED, PI_PARENT_NAME, PI_TOP_LEVEL_NAME, PI_PIID, PI_PTID, PI_PARENT_PIID, PI_TOP_LEVEL_PIID, PT_DISPLAY_NAME, WI.WSID, WI.OWNER_ID, WI.GROUP_NAME, WI.EVERYBODY, WI.REASON, . This problem happens if the column information for the Explorer view is not properly initialized. This happens f.e. if a Process Instance Search without query tables is done and then a process instance is selected and "Related Processes" is clicked. Problem Conclusion: The columns of a view are now properly initialized before the view is shown.
Problem conclusion
Problem fixed iFix available on top of V700 FP4
Temporary fix
Comments
APAR Information
APAR number
IV26369
Reported component name
BUS PRC CHOREOG
Reported component ID
5655FLW11
Reported release
700
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2012-08-17
Closed date
2012-10-31
Last modified date
2012-10-31
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
BUS PRC CHOREOG
Fixed component ID
5655FLW11
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS7J6S","label":"WebSphere Enterprise Service Bus"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: