A fix is available
APAR status
Closed as program error.
Error description
An ASSERT is seen in the sna.err log: 2012-03-11 08:04:01 EDT 4096-19(0-10) E (example.com) ASSERT: File name = ../../p/sappn/nrtpapi.c Line number = 144 Expression = !NB_MEMCMP(thdr->tcid, LOCAL.my_tcid, S_TCID) Stack: nrt_rtp_receive+278(3292F020,33993048,33993048,1) nrt_receive_proc+1A0(3292F020,1,33993048,0) nba_dispatch_input+294(32941720,33993048,F003F580,49B2F20) nba_dispatch_process+CC(32941720,33993048,F003F620,1) nba_schedule_process+154(32941720,2F580C50,200034E,21A) nba_send_ips+308(30001B3,1,3292F020,0) nhp_rtp_nlp+DF0(3292F020,2F580C50,32924820,2F49B048) nhp_queue_handler+5DC(3292F020,2000,2F580C50,0) nba_dispatch_input+294
Local fix
Problem summary
The problem occurs when the following all occur: If a node is restarted quickly and low numbered RTP pipes are in use at the point that the node is stopped (eg @R000004) then a VRN partner will not detect the failure and when it polls after the VRN connection is re-established CS/AIX can mix up the old data with data from a new partner. This leads to the ASSERT (which detects the randomised TCID that CS/AIX generates).
Problem conclusion
Code has been added to ignore the old data.
Temporary fix
Comments
APAR Information
APAR number
IV21485
Reported component name
CS AIX V6.X
Reported component ID
5765E5100
Reported release
631
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-05-21
Closed date
2012-07-16
Last modified date
2013-09-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
IV24781 LI76903 LI76904 LI76905 JR44764 JR46208 LI77297 LI77298
LI77299
Fix information
Fixed component name
CS AIX V6.X
Fixed component ID
5765E5100
Applicable component levels
R640 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPQKF","label":"Communications Server for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"631","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
17 September 2013