IBM Support

IV21373: APPLICATION DATA VALUE FIELD TRUNCATED WHEN EDITED BY THE CICS EXPLORER EVENT BINDING EDITOR.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When creating an event binding file with the CICS Explorer
    Event Binding editor, a problem occurs where the Application
    Data value field can become truncated.
    .
    The problem occurs after you have created the application data
    predicate and entered a value larger than 1 digit in the value
    field. After you save, if you reopen the application data to
    edit it, the value field is truncated down to just 1 digit. You
    can not over type or make this value larger.
    Additional Symptom(s) Search Keyword(s): KIXREVNDB
    

Local fix

  • Open the event binding with a text editor, and change the value
    specified in the XML accordingly.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All CICS Explorer Users                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Application Data value field truncated  *
    *                      when edited by the CICS Explorer Event  *
    *                      Binding editor.                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When editing an existing Application Data Predicate from the
    CICS Explorer Event Binding editor, the value field becomes
    truncated to one digit. This occurs when the types of the field
    is either Signed Halfword, Signed Fullword, Unsigned Halfword or
    Unsigned Fullword.
    

Problem conclusion

  • The application data predicate dialog has been updated with the
    following changes:
    - The application data value field will no longer be truncated
    inappropriately.
    - Minimum allowed values have been updated for Signed Halfword,
    Unsigned Halfword and Unsigned Fullword data types.
    
    For installation instructions please see:
    Ordering Maintenance for the IBM CICS Explorer
    http://www-01.ibm.com/support/docview.wss?uid=swg21380083
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV21373

  • Reported component name

    CICS EXPLORER V

  • Reported component ID

    5655S9701

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-05-16

  • Closed date

    2012-08-07

  • Last modified date

    2012-08-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CICS EXPLORER V

  • Fixed component ID

    5655S9701

Applicable component levels

  • R110 PSY

       UP