Direct link to fix
APAR status
Closed as program error.
Error description
When creating an event binding file with the CICS Explorer Event Binding editor, a problem occurs where the Application Data value field can become truncated. . The problem occurs after you have created the application data predicate and entered a value larger than 1 digit in the value field. After you save, if you reopen the application data to edit it, the value field is truncated down to just 1 digit. You can not over type or make this value larger. Additional Symptom(s) Search Keyword(s): KIXREVNDB
Local fix
Open the event binding with a text editor, and change the value specified in the XML accordingly.
Problem summary
**************************************************************** * USERS AFFECTED: All CICS Explorer Users * **************************************************************** * PROBLEM DESCRIPTION: Application Data value field truncated * * when edited by the CICS Explorer Event * * Binding editor. * **************************************************************** * RECOMMENDATION: * **************************************************************** When editing an existing Application Data Predicate from the CICS Explorer Event Binding editor, the value field becomes truncated to one digit. This occurs when the types of the field is either Signed Halfword, Signed Fullword, Unsigned Halfword or Unsigned Fullword.
Problem conclusion
The application data predicate dialog has been updated with the following changes: - The application data value field will no longer be truncated inappropriately. - Minimum allowed values have been updated for Signed Halfword, Unsigned Halfword and Unsigned Fullword data types. For installation instructions please see: Ordering Maintenance for the IBM CICS Explorer http://www-01.ibm.com/support/docview.wss?uid=swg21380083
Temporary fix
Comments
APAR Information
APAR number
IV21373
Reported component name
CICS EXPLORER V
Reported component ID
5655S9701
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-05-16
Closed date
2012-08-07
Last modified date
2012-08-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CICS EXPLORER V
Fixed component ID
5655S9701
Applicable component levels
R110 PSY
UP