IBM Support

IV19168: LINGERTIME VALUE DISPLAY ACCIDENTALLY REMOVED FROM DEVICE STRUCT URE VIEW AFTER APPLY FP1 (APAR IN ERROR IS IV08192)

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • This APAR is created as AE/MDV APAR with "MDVREGR" class.
    LingerTime value was left off DeviceStructure Display in 3.9
    FP1.  This was not the case in 3.9 GA and is due to a change
    made in APAR IV08192.
    
    | MDVREGR 3.9.0-TIV-ITNMIP-FP0001 |
    

Local fix

  • None
    On the TIP server -
    $PRECISION_HOME/profiles/TIPProfile/etc/tnm/ncimMetaData.xml
    file.  If you compare the GA version to FP1, you can see that
    the three chassis table sections are different - they are
    missing the (datafield) entry for lingerTime, and the table
    section is missing an INNER JOIN with the linger time table.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All ITNM 3.8 FP1 users.                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * LINGERTIME VALUE DISPLAY ACCIDENTALLY REMOVED FROM DEVICE    *
    * STRUCT                                                       *
    * URE VIEW AFTER APPLY FP1 (APAR IN ERROR IS IV08192)          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * ITNM-IP | fix pack | 3.9.0-ITNMIP-FP0002                     *
    * ITNM-IP | fix pack | 3.8.0-ITNMIP-FP0007                     *
    * XML file has Linget time options were removed in FP1.        *
    * Restore back the original (3.9)  ncimMetaData.xml file.      *
    ****************************************************************
    

Problem conclusion

  • The fix will be included in next fixpack
    | MDVREGR 3.9.0-TIV-ITNMIP-FP0002 |
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV19168

  • Reported component name

    TIV NETWK MGR I

  • Reported component ID

    5724S4500

  • Reported release

    390

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-04-09

  • Closed date

    2012-04-12

  • Last modified date

    2013-04-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TIV NETWK MGR I

  • Fixed component ID

    5724S4500

Applicable component levels

  • R390 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSSHRK","label":"Tivoli Network Manager IP Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.9","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: