Fixes are available
January 2012 PTF for XL C for AIX, V11.1
January 2012 PTF for XL C/C++ for AIX, V11.1
April 2012 PTF for XL C for AIX, V11.1
April 2012 PTF for XL C/C++ for AIX, V11.1
July 2012 PTF for XL C/C++ for AIX, V11.1
October 2012 PTF for XL C/C++ for AIX, V11.1
October 2012 PTF for XL C for AIX, V11.1
February 2013 PTF for XL C for AIX, V11.1
February 2013 PTF for XL C/C++ for AIX, V11.1
XL C/C++ for AIX Fix Pack 14 (May 2013 PTF) for 11.1
XL C for AIX Fix Pack 14 (May 2013 PTF) for 11.1
XL C/C++ for AIX Fix Pack 15 (August 2013 PTF) for 11.1
XL C for AIX Fix Pack 15 (August 2013 PTF) for 11.1
XL C/C++ for AIX Fix Pack 16 (November 2013 PTF) for 11.1
XL C for AIX Fix Pack 17 (February 2014 PTF) for 11.1
XL C/C++ for AIX Fix Pack 17 (February 2014 PTF) for 11.1
XL C/C++ for AIX Fix Pack 18 (May 2014 PTF) for 11.1
XL C/C++ for AIX Fix Pack 19 (August 2014 PTF) for 11.1
XL C/C++ for AIX Fix Pack 20 (November 2014 PTF) for 11.1
XL C for AIX Fix Pack 21 (April 2015 PTF) for 11.1
XL C/C++ for AIX Fix Pack 21 (April 2015 PTF) for 11.1
XL C/C++ for AIX Fix Pack 22 (September 2015 PTF) for 11.1
XL C for AIX Fix Pack 23 (March 2016 PTF) for 11.1
XL C/C++ for AIX Fix Pack 23 (March 2016 PTF) for 11.1
XL C for AIX Fix Pack 24 (September 2016 PTF) for 11.1
XL C/C++ for AIX Fix Pack 24 (September 2016 PTF) for 11.1
July 2012 PTF for XL C for AIX, V11.1
XL C for AIX Fix Pack 16 (November 2013 PTF) for 11.1
XL C for AIX Fix Pack 18 (May 2014 PTF) for 11.1
XL C for AIX Fix Pack 19 (August 2014 PTF) for 11.1
XL C for AIX Fix Pack 20 (November 2014 PTF) for 11.1
XL C for AIX Fix Pack 22 (September 2015 PTF) for 11.1
APAR status
Closed as program error.
Error description
When analyzing listing files that contain "xvcpsgnd" instructions, the compiler should be generating more efficient code for the that instruction. Compiler uses register moves xvcpsgndp. But instead, it can make use of the xxlor and xxpermdi instructions. xxlor only takes 2c (can run only on pipe 0). xxpermdi takes 3c (can run only on pipe 1). xvcpsgnd always takes 7c and can run on both pipes. ==> A register move with with xxlor is much faster. ==> 2 register moves can be implemented with xxlor + xxpermdi Moving a register pair can be required for duplicating _Decimal128 values. So, the following instructions: 1435| 000044 xvcpsgnd F0021780 1 LRVS vs0=vs2 1435| 000048 xvcpsgnd F0231F80 1 LRVS vs1=vs3 can be replaced with: xxlor vs0,vs2,vs2 xxpermdi vs1,vs3,vs3,0
Local fix
n/a
Problem summary
Users Affected: Users who use _Decimal128 values which internally makes use of xvcpsgnd can be potentially affected by this issue. Problem Description: The compiler inefficiently creates xvcpsgnd instructions which can potentially be replaced with xxlor and xxpermdi instructions. However, this is not always the case, as it depends on which architecture the final exe is being executed on.
Problem conclusion
Replacing xvcpsgnd with xxlor and xxpermdi is beneficial on PWR7. As a result, the compiler will now recognize such circumstances under the -qtune=pwr7 option and will replace xvcpsgnd with xxlor and xxpermdi.
Temporary fix
Comments
APAR Information
APAR number
IV12845
Reported component name
XL C/C++ AIX
Reported component ID
5724X1300
Reported release
B10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-01-09
Closed date
2012-01-09
Last modified date
2012-01-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
XL C FOR AIX
Fixed component ID
5724X1200
Applicable component levels
Document Information
Modified date:
10 January 2012