IBM Support

IV07550: LOG CONTAINS "SEQUENCE NUMBER OVERFLOW, REUSING 999"

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • PROBLEM DESCRIPTION:
    
    The HUB RAS1 log contains thousands of messages stating
    "Sequence number overflow, reusing 999". Hundreds or thousands
    of these messages occur every second.
    
    RECREATE INSTRUCTIONS:
    - Set the QOMEGAMON_ONLINE situation to have a interval of less
    than 1 minute.
    - Restart the HUB.
    - Problem occurs almost immediately. Check the HUB's RAS1 log
    for the secquence number overflow messages.
    

Local fix

  • Do either one of the following:
    
    
    - Change the interval on the QOMEGAMON_ONLINE situation to be at
    least minute - 3 minutes is recommended. It appears this is set
    to 30 seconds right now.
    
    - Specify the HEARTBEAT_INTERVAL in the TEMS configuration file.
    

Problem summary

  • RAS1 log contains "Sequence number overflow, reusing 999".
    
    The hub monitoring server RAS1 log contains thousands of
    messages stating "Sequence number overflow, reusing 999".
    Hundreds or thousands of these messages occur every second.
    These messages appear just after the monitoring server start.
    
    The problem is caused by the monitoring server heartbeat being
    issued as quickly. This occurs when the QOMEGAMON_ONLINE
    situation has an interval of less than one minute. The situation
    does not have to be started for this problem to occur.
    

Problem conclusion

  • The monitoring server now to includes the "seconds" value from
    the QOMEGAMON_ONLINE situation when determining the monitoring
    server heartbeat interval.
    
    It appears CTIRA_HEARTBEAT can be set in the configuration file
    as another means to control the monitoring server heartbeat
    interval. The variable takes precedence over the value in the
    QOMEGAMON_ONLINE situation.
    
    
    
    The fix for this APAR is contained in the following maintenance
    packages:
    
       | fix pack | 6.2.2-TIV-ITM-FP0007
    

Temporary fix

  • Change the QOMEGAMON_ONLINE interval to be at least one minute.
    Three minutes is the recommended value.
    

Comments

APAR Information

  • APAR number

    IV07550

  • Reported component name

    TEMS

  • Reported component ID

    5724C04MS

  • Reported release

    622

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-09-08

  • Closed date

    2011-09-30

  • Last modified date

    2011-12-15

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    OA38224 OA39002

Fix information

  • Fixed component name

    TEMS

  • Fixed component ID

    5724C04MS

Applicable component levels

  • R622 PSY

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"622"}]

Document Information

Modified date:
30 December 2022