A fix is available
APAR status
Closed as program error.
Error description
Under the panel titled "Configure Paths for a Device", if only a single path is selected to configure instead of "All Paths", then configure path operation (for MPIO device) will fail.
Local fix
Problem summary
Under the panel titled "Configure Paths for a Device", if only a single path is selected to configure instead of "All Paths", then configure path operation (for MPIO device) will fail.
Problem conclusion
Pass in correct options to mkpath command from SMIT PANEL to configure a single path (for an MPIO device).
Temporary fix
Comments
APAR Information
APAR number
IV04482
Reported component name
AIX 5.3
Reported component ID
5765G0300
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2011-08-04
Closed date
2011-08-04
Last modified date
2013-04-07
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
AIX 5.3
Fixed component ID
5765G0300
Applicable component levels
R530 PSY U844896
UP11/10/07 I 1000
PTF to Fileset Mapping
U844896 bos.rte.methods 5.3.11.2
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG11P","label":"APARs - AIX 5.3 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"530","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
07 April 2013