A fix is available
APAR status
Closed as program error.
Error description
Communications Server for AIX, Version 6.4 ------------------------------------------ On a system with CSAIX installed, using cldump or snmpinfo can fail with "genErr at position 1".
Local fix
If SNMP is not being used for monitoring SNA, remove the SNA MIB from the SNMP confiuration. Edit the files /etc/snmp.conf and /etc/snmp.peers to comment out or remove the line: smux 1.3.6.1.4.1.2.6.2.1.7 Route66 Then restart then snmpd service.
Problem summary
USERS AFFECTED: all using snmp tools PROBLEM DESCRIPTION: On a system with CSAIX installed, the commands cldump and snmpinfo fail with "genErr at position 1" PROBLEM SUMMARY: cldump in hacmp failed when snasnmp was running.
Problem conclusion
The CSAIX snasnmp function has been changed to correctly handle a full walk of the MIB.
Temporary fix
snasnmp
Comments
APAR Information
APAR number
IV03869
Reported component name
CS AIX V6.X
Reported component ID
5765E5100
Reported release
631
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-07-27
Closed date
2011-07-27
Last modified date
2011-11-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CS AIX V6.X
Fixed component ID
5765E5100
Applicable component levels
R631 PSY U848721
11/11/18 I 1000
[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSPQKF","label":"Communications Server for AIX"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"631"}]
Document Information
Modified date:
28 September 2021