Error description

  • On AIX booted as 32 bit Operating System running on 64 bit
    hardware, can not monitor DB2 64 bit instance.
    Even after selecting and installing the 64 DB2 Monitoring agent,
    ITM attempts to start the 32 bit DB2 Monitoring agent even
    thought the DB2 instance to monitor is 64 bit.
    
    RECREATE INSTRUCTIONS:
    
    Install a 64 bit version of DB2 on AIX 32 bit OS/64 bit HW.
    Create a 64 bit DB2 instance.
    Select and install the 64 bit DB2 monitoring agent.
    Start the DB2 monitoring agent for the DB2 instance created.
    [ERROR] The 32 bit mode version of the DB2 agent is started and
    fails to monitor the 64 bit DB2 instance.
    
    Approver Initials:    AS
    

Local fix

  • 1. Install 64bit DB2 Agent.
    2. Remove <CANDLEHOME>/registry/udaix523.ver.
    3. Add the following in <CANDLEHOME>/registry/udaix526.ver.
    
       runArch = aix523
       runArch = aix533
    

Problem summary

  • Unable to monitor 64 bit DB2 instances when the operating system
    is booted as 32 bit on 64 bit hardware.
    
    
    On an AIX operating system booted as 32 bit running on 64 bit
    hardware, IBM Tivoli Monitoring cannot monitor 64 bit DB2
    instances. Even after specifically selecting and installing the
    64 bit DB2 monitoring agent, IBM Tivoli Monitoring attempts to
    start the 32 bit DB2 monitoring agent even though the DB2
    instance to monitor is 64 bit.
    

Problem conclusion

  • Allow monitoring of a 64 bit DB2 instance on 64 bit hardware
    even when the operating system is booted in 32 bit mode.
    
    The fix for this APAR is contained in the following maintenance
    packages:
    
       | fix pack | 6.2.2-TIV-ITM-FP0007
       | fix pack | 6.2.2-TIV-ITM-FP0001
    

Temporary fix

Comments

APAR Information

  • APAR number

    IV03537

  • Reported component name

    OMEG DIST INSTA

  • Reported component ID

    5608A41CI

  • Reported release

    622

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-07-20

  • Closed date

    2011-09-29

  • Last modified date

    2012-06-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    OMEG DIST INSTA

  • Fixed component ID

    5608A41CI

Applicable component levels

  • R622 PSY

       UP

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSTFXA","label":"Tivoli Monitoring"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"622"}]

Document Information

Modified date:
30 December 2022