Direct links to fixes
APAR status
Closed as program error.
Error description
Delayed or unresponsive database connections may cause Connect:Direct Windows server to go in a hang state.
Local fix
STRMFT-18066 RK / SS Circumvention: None
Problem summary
Users Affected: Sterling Connect:Direct for Windows 6.3.0 Sterling Connect:Direct for Windows 6.4.0 Problem Description: Multiple database connection request from Connect:Direct Windows server causes it to go in a hang state. Platforms Affected: Windows
Problem conclusion
Resolution Summary: Configured timeout for connection request so that it gets timed out and does not hang indefinitely. Delivered In: Sterling Connect:Direct for Windows 6.3.0.6_iFix035 Sterling Connect:Direct for Windows 6.4.0.4_iFix007
Temporary fix
Delivered In: Sterling Connect:Direct for Windows 6.3.0.6_iFix035 Sterling Connect:Direct for Windows 6.4.0.4_iFix007
Comments
APAR Information
APAR number
IT48985
Reported component name
STR CD FOR WIND
Reported component ID
5725C9908
Reported release
640
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2026-01-22
Closed date
2026-02-24
Last modified date
2026-02-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
STR CD FOR WIND
Fixed component ID
5725C9908
Applicable component levels
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSRRVY","label":"Sterling Connect:Direct for Microsoft Windows"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"640","Line of Business":{"code":"LOB77","label":"Automation Platform"}}]
Document Information
Modified date:
27 March 2026