IBM Support

IT45940: ANR9759W DURING AUDIT LIBRARY WHEN A TAPE DRIVE SLOT EXISTS IN THE LIBRARY BUT HAS NO DRIVE PLUGGED IN

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • The following warning message appears during AUDIT LIBRARY
    command when an empty tape drive slot exists in the library but
    no tape drive is using that slot:
    ANR9759W The server cannot locate the tape drive with the 123
    address because the serial number of the tape drive could not be
    identified.
    
    No tape drive or path can be defined for that slot as there is
    no tape drive here, but for an IBM library, an ITDT INVENTORY
    command shows the drive slot with status abnormal:
    Drive Address 123
    Drive State ................... Abnormal
    ASC/ASCQ ...................... 8200
    Media Present ................. No
    Robot Access Allowed .......... No
    Source Element Address ........ N/A
    Location (Fra/Col/Row/Acc)..... 0/0/0/A (TS3500/4500 only)
    Media Inverted ................ No
    Same Bus as Medium Changer .... Yes
    SCSI Bus Address .............. N/A
    Logical Unit Number ........... N/A
    Volume Tag ....................
    
    
    
    IBM Spectrum Protect Versions Affected: All IBM Spectrum
    Protect Server 8.1 on all supported platforms
    
    Additional Keywords: TS012967868 usecode
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All IBM Storage Protect server users of tape library.        *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description.                                       *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fixing level when available.                           *
    * This problem is currently projected to be fixed in level     *
    * 8.1.23.                                                      *
    * Note that this is subject to change at the discretion of     *
    * IBM.                                                         *
    ****************************************************************
    

Problem conclusion

  • This problem was fixed.
    Platforms fixed:  AIX, Linux, and Windows
    
    ANR9759W The server cannot locate the tape drive with the XYZ
    address because the serial number of the tape drive could not be
    identified.
    
    Explanation
    During the drive inventory operation, no serial number was
    identified
    for the specified tape drive. This error might be caused by a
    hardware or library configuration issue , or the drive is
    removed from
    the specified drive slot. A tape drive must have a serial number
    to be
    used by the server.
    
    SystemAction
    System operation continues.
    UserResponse
    To resolve the error, take one or more of the following actions:
     -Ensure that all tape drives are operational.</li>
     -Verify the library configuration. Drive addresses must be
    consecutively
    numbered, as shown in this example: 100, 101, 102.
    If drive addresses are not consecutively numbered (for
    example,100, 106, 109), correct the issue.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT45940

  • Reported component name

    TSM SERVER

  • Reported component ID

    5698ISMSV

  • Reported release

    81A

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-04-15

  • Closed date

    2024-05-12

  • Last modified date

    2024-05-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TSM SERVER

  • Fixed component ID

    5698ISMSV

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"81A"}]

Document Information

Modified date:
14 June 2024