IBM Support

IT45938: ANR8311E IO ERROR DURING TESTREADY / OFFL OPERATIONS WHILE DOING LABEL LIBV ON LTO-9 MEDIA

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • The following error may occur when labeling new LTO-9 tape
    media:
      ANR8311E An input/output (I/O) error occurred during an
    attempt to  access drive DRVXX (\\.\Tape9) for operation
    TESTREADY. The error number  (errno) is 121 and the return  code
    (rc) is 2863.
    
      ANR8304E Time out error on drive DRVXX (\\.\Tape9) in library
    LIBRXX
      ANR8779E Unable to open drive DRVXX (\\.\Tape9), error number=
    85180.
    
      ANR8311E An input/output (I/O) error occurred during an
    attempt to  access drive DRVXX (\\.\Tape9) for operation  OFFL.
    The error number  (errno) is 1110 and the return  code (rc) is
    2863.
    
      ANR8942E Could not move volume VOLXXXL9 from slot-element 257
    to slot-element 20.
    
      ANR8802E LABEL LIBVOLUME process, 109, for library LIBRXX
    failed.
    
    That happens because new L9 / LZ medias need to follow a media
    optimization function described in the following documentation:
    
      https://www.ibm.com/docs/en/t-tt-and-t?topic=introduction-med
    ia-optimization
    That media optimization is done the first time a new never used
    tape is mounted in a LTO-9 drive, and it may take between 20
    mins to 2 hours.
    That is larger than the timeout used for tape IO operation. The
    timeout is the reason for the error seen in IBM Spectrum Protect
    server.
    
    
    IBM Spectrum Protect Versions Affected:
    
       All IBM Spectrum Protect Server at 8.1.12.0 and higher on all
    supported platforms
      LTO9 support was introduced since 8.1.12.0
    
    Additional Keywords: TS013376018 LTO-9 ULTRIUM ULTRIUM9
    ULTRIUM-9
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All IBM Storage Protect server users of LTO 9 tape drives.   *
    *                                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description.                                       *
    *                                                              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply fixing level when available.                           *
    * This problem is currently projected to be fixed in level     *
    * 8.1.23.                                                      *
    * Note that this is subject to change at the discretion of     *
    * IBM.                                                         *
    ****************************************************************
    

Problem conclusion

  • This problem was fixed.
    Platforms fixed:  AIX, Linux, and Windows
    
    ANR8304E Time out error on drive XYZ in library ABCD library.
    Explanation
    A time out condition occurred while waiting for the given drive
    to
    become ready so that automated library operations could be
    performed.
    If this failure happens in an LTO 9 tape drive and the tape is
    the first time
    to be loaded to the LTO 9 drive, this failure is expected. Check
    the technot
     for detailed info at
    https://www.ibm.com/support/pages/node/6482903
    SystemAction
    The operation fails.
    UserResponse
    Ensure that the DEVICE parameter associated with the drive was
    identified
    correctly in the DEFINE PATH command, and that the device is
    currently
    powered on and ready.
    For using LTO 9 tapes, ensure these LTO 9 tapes are already
    initialized.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT45938

  • Reported component name

    TSM SERVER

  • Reported component ID

    5698ISMSV

  • Reported release

    81W

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2024-04-15

  • Closed date

    2024-05-12

  • Last modified date

    2024-05-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TSM SERVER

  • Fixed component ID

    5698ISMSV

Applicable component levels

[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSGSG7","label":"Tivoli Storage Manager"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"81W"}]

Document Information

Modified date:
14 June 2024