APAR status
Closed as program error.
Error description
The customer upgraded Pcom from v6 on Windows 7 to v15 on Windows 10 The customer uses ehllapi. Host code page 939 PCOM 15.0.0 64bit WinHLLAPI function (033) Copy String to Field RC=9 means System Error Connect PS and Set Cursor function calls work ok (RC=0)
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All Personal Communications 3270 DBCS 64-bit users * **************************************************************** * PROBLEM DESCRIPTION: * * When user passes a single character to the CopyStringToField * * API, the return code is SYSTEM_ERROR = 9 and the character * * is not pasted at the specified cursor location on Japanese * * Windows machines. * **************************************************************** * RECOMMENDATION: * **************************************************************** To reproduce this problem 1) Launch a 3270 Japanese type display session with PCOM v15 64-bit 2) Pass a single character to CopyStringToField API from a EHLLAPI C# application The passed character is not pasted onto the emulator screen and the API returns SYSTEM_ERROR = 9 return code
Problem conclusion
PCSWSAPI.DLL code changes have been made for the 3270 session to paste the single character passed to CopyStringToField API on the emulator screen at the given cursor position.
Temporary fix
Comments
APAR Information
APAR number
IT44288
Reported component name
PCOMM COMBO-ENG
Reported component ID
5639I7000
Reported release
F00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-08-03
Closed date
2023-09-29
Last modified date
2023-09-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSWSAPI
Fix information
Fixed component name
PCOMM COMBO-ENG
Fixed component ID
5639I7000