APAR status
Closed as program error.
Error description
Starting with version 10.1.15, the IBM Storage Protect Plus GUI global preference ?Auto logout (minutes)? is not taken into account. Any started GUI user session stays logged in indefinitely being idle as long as the browser window is kept open. |MDVREGR 10.1.14.1 5737SPLUS| IBM Storage Protect Plus Versions Affected: IBM Storage Protect Plus 10.1.15 and later Additional Keywords: SPP, SPPLUS, TS013466994
Local fix
Do not forget to logout or close the browser after completing the work session.
Problem summary
**************************************************************** * USERS AFFECTED: * * IBM Spectrum Protect Plus level 10.1.15. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Apply the fixing level when available. This problem is fixed * * in IBM Spectrum Protect Plus levels 10.1.15.1 and 10.1.16. * * Note that this is subject to change at the discretion of * * IBM. * ****************************************************************
Problem conclusion
A regression was introduced in which the IBM Spectrum Protect Plus User Interface (UI) did not use the Inactivity Timeout Global Preference as the basis for timing out a UI user session. This regression has been resolved, which times out the user according to the configured Inactivity Timeout Global Preference.
Temporary fix
Comments
APAR Information
APAR number
IT44128
Reported component name
SP PLUS
Reported component ID
5737SPLUS
Reported release
A1E
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2023-07-10
Closed date
2023-08-03
Last modified date
2023-08-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
Platform UI
Fix information
Fixed component name
SP PLUS
Fixed component ID
5737SPLUS
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSNQFQ","label":"IBM Spectrum Protect Plus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"A1E","Line of Business":{"code":"LOB26","label":"Storage"}}]
Document Information
Modified date:
01 February 2024