Error description
Onsmsync exits with 0x3 (Aborted) when exporting cloud (AWS S3) with split objects into multiple pieces in psmGetData. 2022-07-31 20:38:03.728213 416333 415717 smread.c:145 readNSM: return 9894899 (0x96fbf3) 2022-07-31 20:38:03.728226 416333 415717 xbsa_so.c:911 We failed reading the new detail. 2022-07-31 20:38:03.728236 416333 415717 xbsa_so.c:954 psmGetData: return 3 (0x03) 2022-07-31 20:38:03.728247 416333 415717 xbsa_so.c:1921 psmExportObject: BSAGetData returned 3
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC16 and 14.10.xC9. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 12.10.xC16Â or 14.10.xC9. * ****************************************************************
Problem conclusion
Fixed in Informix Server 12.10.xC16 and 14.10.xC9.
Temporary fix
Comments
APAR Information
APAR number
IT41844
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
E10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-08-24
Closed date
2022-10-05
Last modified date
2024-09-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFORMIX SERVER
Fixed component ID
5725A3900
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"E10","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
25 September 2024