Error description

  • Details:
    com.sterlingcommerce.scc.common.NodeServiceConnectionException:
    java.sql.SQLException: [PWS9801] Function rejected by user exit
    program SAFENET in PCSECLIB. Cause . . . . . : User exit program
    SAFENET in library PCSECLIB called for the function
    and returned an indication that the function should not be done.
    

Local fix

  • STRRTC - MFT-13457
    VS / SF
    Circumvention: None
    

Problem summary

  • Description of issue: While monitoring CD i5 server errors occur
     causing "java.sql.SQLException: [SQL7049] An internal object
    limit has been exceeded." errors to be output to the
    engine/event processor log file.
    

Problem conclusion

  • Description of fix: Updated logic that ascertains whether or not
     the CD i5 stat file has a SEQUENCE column to close its result
    set and for the logic that invoked it to only do so once at
    signon time instead of prior to each request for statistics.
    
    Note this new logic may cause an i5 security exit to say there's
    an issue, which prevents Control Center from retrieving any
    statistics at all from the server and results in Control Center
    indicating the server is down.  Until the security exit on the
    CD i5 system can be rectified, two new engine properties may be
    used to avoid the code that's triggering the security exit from
    saying there's a problem - CHECK_I5_STAT_FILE_COLUMNS and
    I5_STAT_FILE_SEQUENCE_PRESENT.  CHECK_I5_STAT_FILE_COLUMNS
    defaults to true, but when it is set to false, Control Center
    will rely on the value of I5_STAT_FILE_SEQUENCE_PRESENT, which
    defaults to false, to know if the cdstatfile database has the
    new SEQUENCE column, instead of the logic that is triggering the
    security exit from saying that is a problem.
    
    Note a version of this change was made for 6.2.0 - MFT-13457,
    but it used different property names, ALLOW_CD_STAT_FILE_CHECK
    for CHECK_I5_STAT_FILE_COLUMNS, and CD_STAT_FILE_HAS_SEQUENCE
    for I5_STAT_FILE_SEQUENCE_PRESENT.  The previous property names
    are no longer supported, and will be ignored if still specified.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT41383

  • Reported component name

    STR CONTROL CEN

  • Reported component ID

    5725D0200

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-06-29

  • Closed date

    2022-08-30

  • Last modified date

    2023-04-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    STR CONTROL CEN

  • Fixed component ID

    5725D0200

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9GLA","label":"IBM Control Center"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
27 April 2023