Error description
With HDR secondary paired to primary and DRINTERVAL is set to 30 or more, on primary server we get -242/-154 error in online.log when ever Auto Update Statistics Evaluation task is run. 06/24/22 09:01:27 SCHAPI: last statement CREATE INDEX aus_work_info_idx2 ON aus_work_info(aus_info_partnum) 06/24/22 09:01:27 SCHAPI: [Auto Update Statistics Evaluation 47-4] Error -242 Could not open database table(informix.aus_work_info). 06/24/22 09:01:27 SCHAPI: [Auto Update Statistics Evaluation 47-4] Error -154 ISAM error: Lock timeout Expired Auto Update Statistics Evaluation task drops and re-creates some tables in sysadmin database, when this task re-creates the index, primary server will ship the newly created indexes. In this process we get -242 error while AUS Evaluation task creating the index aus_work_info_idx2 on aus_work_info. If we set DRINTERVAL to 0, then HDR_TXN_SCOPE takes precedence and we no longer see this error. We don't see -242 error when we set the DRINTERVAL to smaller value compared to default value.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC16 and 14.10.xC9. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 12.10.xC16 or 14.10.xC9. * ****************************************************************
Problem conclusion
Fixed in Informix Server 12.10.xC16 and 14.10.xC9.
Temporary fix
Comments
APAR Information
APAR number
IT41349
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
C10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2022-06-28
Closed date
2023-05-15
Last modified date
2023-05-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFORMIX SERVER
Fixed component ID
5725A3900
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
15 May 2023