IBM Support

IT41031: FOR API GATEWAY, REDACTED DATA IN ASSEMBLY LOG ARE NOT MASKED FOR THE ERROR FLOW WHILE NO "ROOT" PROPERTY IS DEFINED

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • For API Gateway, redacted data in assembly log are not masked
    for the error flow while no "root" property is defined.
    
    
    For example, when API is configured with the following:
         - log:
             version: 2.0.0
             title: log
             mode: gather-only
         - redact:
             version: 2.0.0
             title: redact
             redactions:
               - action: redact
                 path: log.request_body.a
               - action: redact
                 path: log.response_body.b
    
    In error case (for example, when there is an Invoke policy at
    the front that the response from the backend server is HTTP
    40X), the data for request_body and response_body are not
    obfuscates with "*"s in APIC Analytics.
    

Local fix

  • For the redact policy, define a value in "root"
    

Problem summary

  • For API Gateway, redacted data in assembly log are not masked
    for the error flow while no "root" property is definted.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT41031

  • Reported component name

    DATAPOWER

  • Reported component ID

    DP1234567

  • Reported release

    18X

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-05-25

  • Closed date

    2022-07-21

  • Last modified date

    2022-09-08

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DATAPOWER

  • Fixed component ID

    DP1234567

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateways"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"18X","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date: