IBM Support

IT40095: DATABASEEXCEPTION BIP2322E: DATABASE ERROR: SQL STATE ''22018''

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • The error "Invalid character value" is seen when inserting dates
    using the "to_date" function and SYSDATE.  The resulting error
    is seen:
    
    DatabaseException BIP2322E: Database error: SQL State
    ''22018''; Native Error Code '0'; Error Text ''[IBM][ODBC Oracle
    Wire Protocol driver]Invalid character value. Error in parameter
    X.''.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM Integration Bus v10 and IBM App Connect
    Enterprise v11 and v12 using ODBC connectivity to Oracle.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    A message flow that inserts dates into an Oracle table using the
    "to_date" function and SYSDATE may see the following error:
    
    DatabaseException BIP2322E: Database error: SQL State ''22018'';
    Native Error Code '0';
    Error Text ''[IBM][ODBC Oracle Wire Protocol driver]Invalid
    character value. Error in parameter X.''.
    

Problem conclusion

  • The product now includes an updated DataDirect ODBC Oracle
    driver that resolves the issue.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.26
    v11.0      11.0.0.17
    v12.0      12.0.4.0
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT40095

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-03-01

  • Closed date

    2022-05-31

  • Last modified date

    2022-05-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0"}]

Document Information

Modified date:
02 June 2022