  • Closed as program error.

Error description

  • If integration node take more time to shutdown than the
    specified wait time in mqsistop command(mqsistop -w), expected
    return message is "BIP8016E: Cannot confirm the component has
    stopped" . It is correctly working on Windows. But on Unix,
    mqsistop is returning "BIP8071I: Successful command completion"
    instead of BIP8016E.
    

Local fix

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM App Connect Enterprise V11.0 and V12.0
    executing mqsistop command on AIX or Linux platform.
    
    
    Platforms affected:
    AIX, Linux on x86-64 platform, Linux on zSeries platform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    If the integration node takes more time to shutdown than the
    specified wait time in mqsistop command(mqsistop -w), expected
    return message is "BIP8016E: Cannot confirm the component has
    stopped". But on AIX and Linux platform,  mqsistop is returning
    "BIP8071I: Successful command completion" instead of BIP8016E.
    

Problem conclusion

  • mqsistop -w now returns BIP8071I if the integration node takes
    more time to shutdown than the specified wait time.
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v11.0      11.0.0.17
    v12.0      12.0.4.0
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT39801

  • Reported component name

    APP CONNECT ENT

  • Reported component ID

    5724J0550

  • Reported release

    B00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-01-31

  • Closed date

    2022-05-31

  • Last modified date

    2022-05-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    APP CONNECT ENT

  • Fixed component ID

    5724J0550

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B00"}]

Document Information

Modified date:
02 June 2022