IBM Support

IT39507: MONITORING EVENTS ARE NOT EMITTED FROM PASSTHROUGH NODES OF COMPILED MESSAGE FLOW

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • When the bar file is built using the 'compile and in-line
    resources' option or when the message flow is migrated from the
    IBM integration bus, its seen that the passthrough nodes inside
    the flow fail to emit monitoring event configured on the node
    

Local fix

  • Build the bar file without 'compile and in-line resources'
    option and redeploy
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of App Connect Enterprise V11.0 and V12.0 with
    monitoring event configured on PASSTHROUGH node.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    When monitoring event is configured on a Passthrough node in a
    message flow deployed as compiled message flow (ie, when the bar
    file is built with 'Compile and in-line resources' option
    selected from the toolkit or when the message flow is migrated
    from previous versions of the product),  the events are not
    getting generated/emitted.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    IT39507

  • Reported component name

    APP CONNECT ENT

  • Reported component ID

    5724J0550

  • Reported release

    B00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-12-28

  • Closed date

    2022-05-31

  • Last modified date

    2022-05-31

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    APP CONNECT ENT

  • Fixed component ID

    5724J0550

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B00"}]

Document Information

Modified date: