Error description

  • ACE skips authorization check on the userid under which mqsi
    commands are run. Customers migrated from IIB may spot this
    change in behavior.
    

Local fix

  • NA
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All users of IBM App Connect Enterprise V11.0 and V12.0 who
    would like to impose administration security on mqsi commands.
    
    
    Platforms affected:
    MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    A user in IBM Integration Bus V10.0 or older versions can impose
    administration security on mqsi commands by revoking permission
    of 'mqbrkrs' group on the SYSTEM.BROKER.AUTH* queues. However,
    ACE  gives full permissions,  to a user running mqsi command, if
    it is a member of mqbrkrs group.
    

Problem conclusion

  • The default behavior of App Connect Enterprise is not to use
    authorization on IPC calls and hence the fix for this issue is
    made by adding a new property named '<span
    style="background-color:rgb(255, 255,
    255)">localIPCAuthorizationEnabled </span>' under <span
    style="background-color:rgb(255, 255, 255)">RestAdminListener.
    Setting localIPCAuthorizationEnabled=true will enable
    authorization security on mqsi commands. </span>
    
    The property can be set either by editing the node.conf.yaml
    file or by using mqsichangeproperties command as below
    
    mqsichangeproperties IIB_MQ_AUTH_V11 -b RestAdminListener -n
    localIPCAuthorizationEnabled -v true
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v11.0      11.0.0.17
    v12.0      12.0.4.0
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT38712

  • Reported component name

    APP CONNECT ENT

  • Reported component ID

    5724J0550

  • Reported release

    B00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-10-15

  • Closed date

    2022-04-13

  • Last modified date

    2022-04-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    APP CONNECT ENT

  • Fixed component ID

    5724J0550

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDR5J","label":"IBM App Connect Enterprise"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B00"}]

Document Information

Modified date:
14 April 2022