A fix is available
APAR status
Closed as program error.
Error description
When the following 2 parameters are present in the Keyboard-Section of the Workstation File (WS), PCSWS.EXE crashes. [Keyboard] PFKeysRepeating=Y EnterKeyRepeating=Y Enabling only one or the other results to the same PComm crash. Upon checking the event log it points to the keyboard DLL error. Faulting application name: pcsws.exe, version: 14040.0.21123.1387, time stamp: 0x60904a76 Faulting module name: PCSKBD.dll, version: 14040.0.21123.1387, time stamp: 0x60905b80 Exception code: 0xc0000005 Fault offset: 0x0000000000002879 Faulting process id: 0x1a82c Faulting application start time: 0x01d7848e8b3fd690 Faulting application path: C:\Program Files\IBM\Personal Communications\pcsws.exe Faulting module path: C:\Program Files\IBM\Personal Communications\PCSKBD.dll Report Id: 4a786599-5117-4ee3-a304-77262813e22f Faulting package full name: Faulting package-relative application ID: The issue is present in PComm v14.0.1 and is recreatable also in PComm v14.0.4 The permanent fix will be added to the next release of PComm.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All 64-bit IBM Personal Communications users * **************************************************************** * PROBLEM DESCRIPTION: * * Using certain keywords in the Keyboard section of the WS * * file causes PCOMM v14 64-bit to crash. * **************************************************************** * RECOMMENDATION: * **************************************************************** The below listed keywords have a default value of N (NO). If the keyword value is set to Y (YES) the emulator session crashes when starting. [Keyboard] PFKeysRepeating=Y EnterKeyRepeating=Y
Problem conclusion
PCSKBD.DLL code changes are made to accept the updated keyword value in the session file.
Temporary fix
Comments
APAR Information
APAR number
IT37952
Reported component name
PCOMM COMBO-ENG
Reported component ID
5639I7000
Reported release
E00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-08-10
Closed date
2021-12-08
Last modified date
2021-12-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSKBD
Fix information
Fixed component name
PCOMM COMBO-ENG
Fixed component ID
5639I7000