Error description
oncheck -ci|-cI index checking would not detect duplicates in a table if they share the same key entry (two entries with same values would be found and reported, though.)
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC15 and 14.10.xC7. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 12.10.xC15 or 14.10.xC7 (when * * available). * ****************************************************************
Problem conclusion
Fixed in Informix Server 12.10.xC15 and 14.10.xC7.
Temporary fix
Comments
APAR Information
APAR number
IT37370
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
C10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-06-22
Closed date
2021-08-26
Last modified date
2024-09-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFORMIX SERVER
Fixed component ID
5725A3900
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
25 September 2024