  • Closed as program error.

Error description

  • If a message number is not found in the catalog, then the
    integration server logs the following error in the
    syslog
    
    BIP2176S: Could not find message '39978' in catalog
    'installdir/server/messages/En_US/BIPmsgs.cat', inserts are '1'
    '2' '3'
    
    When the BIP2176S is reported, it is noted that the
    integration server memory is growing
    

Local fix

  • Avoid BIP2176S by including the message number in the catalog.
    

Problem summary

  • ****************************************************************
    USERS AFFECTED:
    All Users of <span style="background-color:rgb(255, 255,
    255)">IBM App Connect Enterprise V11.0 and </span>IBM
    Integration Bus V10.0 hitting a <span
    style="background-color:rgb(255, 255, 255)">BIP2176S
    error.</span>
    
    
    Platforms affected:
    z/OS, MultiPlatform
    
    ****************************************************************
    PROBLEM DESCRIPTION:
    If a message number is not found in the catalog, then the
    integration server logs the following error in the Syslog
    
    BIP2176S: Could not find message '39978' in catalog
    'installdir/server/messages/En_US/BIPmsgs.cat', inserts are '1'
    '2' '3'
    
    When the BIP2176S is reported, it is noted that the integration
    server memory is growing
    

Problem conclusion

  • The product no longer leaks memory when a <span
    style="background-color:rgb(255, 255, 255)">BIP2176S is
    thrown.</span>
    
    ---------------------------------------------------------------
    The fix is targeted for delivery in the following PTFs:
    
    Version    Maintenance Level
    v10.0      10.0.0.24
    v11.0      11.0.0.13
    v12.0      12.0.2.0
    
    The latest available maintenance can be obtained from:
    http://www-01.ibm.com/support/docview.wss?rs=849&uid=swg27006041
    
    If the maintenance level is not yet available,information on
    its planned availability can be found on:
    http://www-1.ibm.com/support/docview.wss?rs=849&uid=swg27006308
    ---------------------------------------------------------------
    

Temporary fix

Comments

APAR Information

  • APAR number

    IT36497

  • Reported component name

    INTEGRATION BUS

  • Reported component ID

    5724J0540

  • Reported release

    A00

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-04-08

  • Closed date

    2021-06-07

  • Last modified date

    2021-10-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    INTEGRATION BUS

  • Fixed component ID

    5724J0540

Applicable component levels

[{"Line of Business":{"code":"LOB45","label":"Automation"},"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSNQK6","label":"IBM Integration Bus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.0"}]

Document Information

Modified date:
13 October 2021